Safety information and Maintenance
(Part of the Operating Instructions for Safety System MGB-AR/MGB-AP)
Inspection and service
Danger! Loss of the safety function because of dam-
age to the system. In case of damage, the affected
module must be replaced completely. Replacement
of individual parts of a module (e. g. parts of the
evaluation module) is not permitted.
Exception: Pre-assembled replacement lids (available
as spare parts for some MGB versions).
Regular inspection of the following is necessary to
ensure trouble-free long-term operation:
Check the switching function
f
Check the secure fastening of the devices and the
f
connections
Check for soiling (e.g. the ventilation slots on the
f
housing)
Check the safe function of the safety guard par-
ticularly
after any setup work
f
each time after the replacement of an MGB module
f
after an extended period without use
f
after every fault
f
after any change to the DIP switch setting
f
No servicing is required, repairs to the device are only
allowed to be made by the manufacturer.
Technical data (extract)
Parameter
Value
Operating voltage U
B
(reverse polarity protected,
24 V DC +10% / -15%
regulated,
(PELV)
residual ripple < 5 %)
Auxiliary voltage U
A
(reverse polarity protected,
24 V DC +10% / -15%
regulated,
(PELV)
residual ripple < 5 %)
Current consumption I
80 mA
B
(no load on any outputs)
Current consumption with
guard locking solenoid I
350 mA
A
(with active guard locking and
unloaded outputs O1 ... O4)
- Additional current
consumption for version with
max. 20 mA
controls and indicators in the
cover
External fuse
see operating
instructions on CD/DVD
Safety outputs OA/OB
Semiconductor outputs,
p-switching, short circuit-
proof
Output voltage U
/U
1)
OA
OB
HIGH
U
/ U
U
-2V ... U
OA
OB
B
LOW
U
/ U
0 ... 1 V DC
OA
OB
Switching current per safety
1 ... 200 mA
output
1) Values at a switching current of 50 mA without taking into ac-
count the cable lengths.
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49 711 7597-0 Fax +49 711 753316 info@euchner.de www.euchner.com
Key:
1 Cover for mechanical release
2 LED indicator
3 DIP switches
4 Terminals X2 -X5
5 Locking bar
6 Depending on version: Cable entry 20x1.5 or plug connector
7 Auxiliary marking for maximum permitted mounting distance
Note: Depending on the version, additional controls and indicators may be integrated into the cover and
a mounting plate can be included. See enclosed data sheet.
Figure 1: Interlocking/locking module MGB-L.-...
1
3
B
4
Key:
1 Door handle
2 Locking pins for housing cover and handle
adjustment
3 Lockout bar
4 Bolt tongue
Figure 2: Handle module MGB-H-...
1
5
7
2
Key:
1 Door handle
2 Setscrew
3 Cover
4 Actuation axis, length 110 mm
5 Protective sleeve
Figure 3: Escape release MGB-F-... (optional)
2
3
4
6
1
2
3
4
5