HYDRAULIC OIL REPLACEMENT PROCEDURE
One of the most important maintenance tasks is to change the hydraulic oil yearly. Under heavy
usage the oil should be changed every nine months. It is important to change the oil regularly to
prevent its breakdown which leads to the damaging of components. The oil filter should be
changed at the same time as the hydraulic oil. A clean filter prevents particles from damaging the
other components in the system.
Replace the hydraulic fluid as follows:
- Disconnect power to unit.
- Remover the front top panel on the main console.
- Remove chrome vent cap from breather pipe located beside electric motor.
- Remove plug bolt from bottom left front corner of main console to drain oil into your catch pail.
- Remove oil filter.
- Replace plug bolt.
- Refill unit through breather pipe using approximately 12 U.S. gallons of Tellus 32 hydraulic oil
(oil should be 6 1/2" deep in tank).
- Install new oil filter (Part# SE50094).
- Replace chrome vent cap and front top panel.
- Reconnect power to unit.
- Run unit to remove any air in the lines.
NOTE: Mixer may run rough and noisy for one or two hours if air has become trapped in the line.