This product is warranted for one year from the date of purchase or two
years from the date of manufacture, whichever occurs first. Subject to the
conditions hereinafter set forth, the manufacturer will repair or replace to the
original consumer, any portion of the product which proves defective due to
defective materials or workmanship. To obtain warranty service, contact the
dealer from whom the product was purchased. The manufacturer retains
the sole right and option to determine whether to repair or replace defective
equipment, parts or components. Damage due to conditions beyond the
control of the manufacturer is not covered by this warranty.
tHIS WaRRanty WILL not appLy: (a) To defects or malfunctions
resulting from failure to properly install, operate or maintain the unit in
accordance with printed instructions provided; (b) to failures resulting
from abuse, accident or negligence or use of inappropriate chemicals or
additives in the water; (c) to normal maintenance services and the parts
used in connection with such service; (d) to units which are not installed in
accordance with normal applicable local codes, ordinances and good trade
practices; and (e) the unit is used for purposes other than for what it was
designed and manufactured.
RetURn of WaRRanteD CoMponentS: Any item to be repaired
or replaced under this warranty must be returned to the manufacturer at
Kendallville, Indiana or such other place as the manufacturer may designate,
freight prepaid.
In those instances where damages are incurred as a result of an alleged pump failure, the homeowner must
1. The system is designed for installation in sumps with
minimum diameter of 18" and depth of 22". For smaller
applications, consult factory.
2. Remove all debris from the pit before installation.
3. Be sure that the pump is clamped securely to the primary
pump discharge pipe and that the two pumps do not interfere
with each other.
4. Install a serviceable check valve in the discharge line.
5. Install a filter or strainer in the water supply line before the
1. DO read all installation materials supplied with the pump.
2. DO inspect unit for any visible damage caused by shipping.
Contact dealer if unit appears to be damaged.
3. DO clean all debris from the pit before installation.
4. DO install a union check valve (see STEP 3) in the
discharge line. DO NOT use a discharge pipe smaller than
the recommended pump discharge sizes.
5. DO install a filter or strainer in the water supply line before the
pump to prevent small particles from clogging the operating
valve.
6. DO test the pump immediately after installation to be sure
that the system is working properly.
7. DO review all applicable local and national codes and verify
that the installation conforms to each of them.
LIMITED WARRANTY
retain possession of the pump for investigation purposes.
Helpful Hints For Easy Installation
Do's And Don'ts For Installing A Unit
© Copyright 2015 Star Water Systems All rights reserved.
tHe WaRRanty pRoVIDeD HeReIn IS In LIeU of aLL otHeR
eXpReSS WaRRantIeS, anD May not Be eXtenDeD oR MoDIfIeD
By anyone. any IMpLIeD WaRRantIeS SHaLL Be LIMIteD to
tHe peRIoD of tHe LIMIteD WaRRanty anD tHeReafteR aLL
SUCH IMpLIeD WaRRantIeS aRe DISCLaIMeD anD eXCLUDeD. tHe
ManUfaCtUReR SHaLL not, UnDeR any CIRCUMStanCeS, Be
LIaBLe foR InCIDentaL, ConSeQUentIaL oR SpeCIaL DaMageS,
SUCH aS, BUt not LIMIteD to DaMage to, oR LoSS of, otHeR
pRopeRty oR eQUIpMent, LoSS of pRofItS, InConVenIenCe
, oR otHeR InCIDentaL oR ConSeQUentIaL DaMageS of any
type oR natURe. tHe LIaBILIty of tHe ManUfaCtUReR SHaLL
not eXCeeD tHe pRICe of tHe pRoDUCt Upon WHICH SUCH
LIaBILIty IS BaSeD.
This warranty gives you specific legal rights, and you may have other rights
which vary from state to state. Some states do not allow limitations on
duration of implied warranties or exclusion of incidental or consequential
damages, so the above limitations may not apply to you.
WaRRanty VaLID In CanaDa anD MeXICo.
pump. Size the filter/strainer properly to minimize pressure
drop, while retaining particles 0.020" (0.5 mm) in diameter
and larger.
6. Test the unit immediately after installation. Refer to STEP 5.
7. Check the Float ON/OFF levels per STEP 2 of the
instructions.
8. Keep the model number, date code, and installation
instructions in a convenient location for future reference.
8. DO NOT use the Home Guard
DO NOT use the Home Guard
wastewater, sewage, effluent, or water with debris in it.
9. DO NOT use a garden hose. Garden hose is not designed
to hold municipal pressure indefinitely and could leak or
burst causing flooding. The Home Guard
permanent piping method such as copper, PEX, or CPVC.
10. DO install the Home Guard
supply line.
11. DO install a union or other quick-disconnect fitting to make
the pump accessible for servicing on both the water supply
and discharge piping.
12. DO install a dedicated shut-off valve on the water supply line
within 6 ft. (1.8 m) of the Home Guard
2
Optima with hot water.
®
Optima to remove
®
Optima requires a
®
Optima pump with only a ¾"
®
Optima.
®