DIGITAL INSULATION TESTER
SAFETY INFORMATION
• Read the following safety information carefully before
attempting to operate or service the tester.
• To avoid damages to the tester do not apply the signals
which exceed the maximum limits shown in the technical
specifications tables.
• Do not use the tester or test leads if they look damaged. Use
extreme caution when working around bare conductors or
bus bars.
• Accidental contact with the conductor could result in electric
shock.
• Use the tester only as specified in this manual; otherwise,
the protection provided by the tester may be impaired.
• Read the operating instructions before use and follow all
safety Information.
• Caution when working with voltages above 60V DC or
30V AC RMS due to electrical shock hazard.
• Before taking resistance measurements or testing acoustic
continuity, disconnect circuit from main power supply and
all loads from the circuit.
SAFETY SYMBOLS:
•
Caution: please refer to this manual before using the
tester.
•
Dangerous voltages.
•
Tester is protected throughout by double insulation or
reinforced insulation.
• When servicing, use only specified replacement parts.
• CE ; complies with EN-61010-1
1. 1. SPECIFICATIONS
1-1 GENERAL INFORMATION
Environment conditions:
• Installation Category III
• Pollution Degree 2
• Altitude up to 2000 meters
• Indoor use only
• Relative humidity 80% max.
• Operation temperature 0~40ºC
Maintenance & Cleaning:
• Repairs or servicing not covered in this manual should only
be performed by qualified personnel.
• Periodically wipe the case with a dry cloth. Do not use
abrasives or solvents on this tester.
Display:
• Large LCD dual display.
Measurement Range:
• 4000MΩ/125V, 4000MΩ/250V,
8
4000MΩ/500V, 4000MΩ/1000V, 400Ω/BZ,
1000V/DCV, 750V/ACV
Sampling Rate:
• 2.5 times per second.
Zero Adjustment:
• Automatic adjustment.
Over Range Indicator:
• "OL" of highest digit is displayed.
Low Battery Indication:
• The icon
is displayed when the battery voltage drops
below the operating voltage.
Operating Temperature:
• 0ºC to 40ºC (32ºF to 104ºF) and Humidity below 80% RH
Storage Temperature:
• -10ºC to 60ºC (14ºF to 140ºF) and Humidity
below 70% RH
Power source:
• 9 V DC (6x1.5V Size "AA" battery or Equivalent)
Dimensions:
• 200(L) x 92(W) x 50(H) mm
Weight:
• Approx 700 g included batteries
Accessories:
• 2x test lead points (black & red).
• 1x crocodile test lead.
• 1x strap.
• 6 pcs battery.
• Carrying case.
• Manual.
1-2 ELECTRICAL SPECIFICATIONS
Accuracy:
±(...% of reading +...digits) at 23ºC±5ºC,below 80% RH.