6. Disconnect the power plug from the power socket.
7. When the charging process has been completed, disconnect the external
power adapter from the power supply socket on the bank note validator.
► The bank note validator can now be used as a portable device.
8. Charge and discharge the device every 15 days, otherwise the service
life of the battery will be impaired.
The charging time required is one hour. A fully charged battery can test up
to 500 bank notes. The battery can be used for up to 4 hours.
Software Update
You can complete a software update with the aid of a USB flash drive with a
maximum of 8 GB.
More detailed information on software updates is available at the following
internet address: www.go-europe.com.
Technical Data
Model
Counting speed
Capacity
Thickness of bank notes
Power supply
Power consumption
Power adapter plug
Rechargeable battery (option)
Operating time with full battery
Temperature and rel. humidity
Dimensions
Weight
NC 375
More than 60 pieces/minute
Maximum value: 99.995 €/£/$/₺
0.075 mm to 0.15 mm
100-240 V (AC); 50/60 Hz
12 W
12 V (DC); 1 A
Lithium-ion battery 12 V; 600 mAh
Up to 4 hours
0 – 40 °C and 40 – 90%
133 × 155 × 89 mm
0.53 kg
G
Technical Data