HIGH PRESSURE WASHER SHUTDOWN -
POSSIBLE FAULTS
1) High pressure washer not used for more than 20
min., high pressure washer in total stop mode (TSI).
This is signalled by indicator light C) flashing.
2) Low fuel level: the burner shuts down and not hot
water is delivered.
The fault is signalled by indicator light D) on steady.
3) 200h programmed maintenance interval expired.
The light will go off following maintenance by the au-
thorised service centre.
The fault is signalled by indicator light E) on steady.
4) Micro-leaks detected or water nozzle clogged: the
high pressure washer shuts down.
The fault is signalled by indicator light F) flashing.
5) No water: After 3 minutes of operation with no
water detected, the high pressure washer shuts
down.
The fault is signalled by indicator light F) flashing.
6) Motor thermal protector activated: the high pres-
sure washer shuts down.
The fault is signalled by indicator light G) flashing.
N.B. To reset the fault signals, turn main switch
"A" to pos."0" and then back to pos. "I".