DESCRIPTION OF SYMBOLS
SWITCHING OF THE PUMP
MOTOR.
DETERGENT
DELIVERY SELECTOR.
Level indicator light.
LIGHTING THE BURNER /
TEMPERATURE
MENT.
Temperature indicator light.
MAINS POWER.
FAULT INDICATOR
FUEL LEVEL
CONTROL PANEL
A - On/off switch.
B - Lighting the Burner / Temperature adjustment.
C - Power indicator light.
D - Diesel level indicator light.
E - Fault indicator light.
F - Descaler level indicator light.
G - Detergent Solution level indicator light.
H - Temperature indicator light.
USING THE CLEANER
Start the cleaner by turning the selector switch "A"
to pos. "I".
In this position, you can control the water tempera-
ture from minimum to maximum, by using regulator
"B".
Warning
The high pressure water jet generates a reaction for-
ce in the lance. Keep a firm grip on the lance handle.
By placing switch "A" on pos. II "ECO", the tempe-
6
rature regulator "B" sets the water temperature at a
preset value of 60°C.
By placing switch "A" on pos. III "Chem", you activate
the supply of the detergent solution.
Use regulator "B" to control the water temperature up
to a maximum of 60°C.
SOLUTION
SIGNALS AND FAULTS DISPLAYED
Display:
If swtich "A" is on pos I, pressure > 32bar, the display
reads "Max 100°C".
With a regulated pressure < 32bar, the display reads
ADJUST-
"140°C".
Displaying working hours:
By placing switch "A" on pos I and pressing key "+"
one time, you can view the lance opening, number
followed by "#"
By pressing key "+" two times, the display shows
working hours using hot water.
By pressing key "+" three times, the display shows
working hours using cold water.
By pressing key "-" the display shows working hours
using hot water.
By pressing the key "ESC", you exit directly from the
menu and you go back to the preset temperature.
Displaying submenus:
Pressing key "OK" for more than 2 seconds displays
4 submenus. To move forward and backward, press
key "+" and "-" respectively.
1) Lang: It allows you to choose the language in whi-
ch the alarms will be displayed. Pressing key "OK"
will display the preset language. Pressing key "+"
and "-" allows you to select your preferred language.
Confirm language by pressing key "OK".
Press key "ESC" to go back to the main submenu.
2) Teco HP: It allows you to change the preset tem-
perature on the "ECO" function (Switch "A" in pos.
II). By pressing key "OK" it displays the temperature
value. To change it, press key "+" and "-". The va-
lue can be set in an interval between 20 and 100°C.
Confirm by pressing key "OK".
Press key "ESC" to go back to the main submenu.
3) Qty Chem: It allows you to select the quantity of
detergent solution to use (switch "A" in pos. II". You
can select 4 values comprises between 0.1 and 0.4.
The preset value is 0.2. Select the preferred value
by pressing key "+" and "-". Confirm by pressing key
"OK".
Press key "ESC" to go back to the main submenu.
4) Version: It allows you to view the version of the
software of the electrical bord, which has been in-
stalled.
EN - english