Assembly and Disassembly
The FR902 Series Dispenser Cabinet contains a 900 Series Meter, internal plumbing, and electrical switch. When
referencing "Item Numbers" in each procedure, refer to diagram on page 9 for dispenser item number parts, and
the diagram on page 11 for meter item numbers.
WARNING
TURN ALL POWER OFF TO THE DISPENSER AND PUMP AT THE BREAKER PRIOR TO
PERFORMING ANY SERVICE. Release any pressure in the piping, hoses, and nozzle prior
to performing any service. Failure to comply with these warnings can result in explosion,
fire, bodily injury, and possibly death.
Cabinet Assembly (refer to page 9 for item # diagram)
Access to the internal components of the 902 Series dispenser is gained by removing the metal cabinet cover (item 3).
To do this, pull the reset knob (item 16) out by grasping it and pulling it firmly away from the cabinet. Next, remove
the 3 large Phillips head screws from the sides and back of the cabinet assembly (item *). The metal cabinet cover
can now be removed from the cabinet base (item 1). Use caution when lifting the metal cabinet off the base plate to
minimize the possibility of scratching the clear plastic window.
Counter Assembly (refer to page 11 for item # diagram)
For access to the counter assembly:
1.
Remove the two screws (item 19) to extract the counter mechanism.
2.
Reassemble by reversing this procedure.
Meter Chamber Assembly (refer to page 11 for item # diagram)
The Meter Chamber Assembly consists of upper and lower chambers, a nutating disc, and four screws.
1.
To expose the meter chamber assembly, gear train and seal remove 4 screws (item 23).
2.
The meter chamber can be dislodged by removing 4 screws (item 21).
Reassemble by reversing this procedure.
NOTICE
If replacing any components of the meter chamber, the complete assembly must be
replaced due to its precision method of construction. This will assure a proper fit, and
correct operation of the chamber.
Gear Train and Seal (refer to page 11 for item # diagram)
To disassemble the gear train and seal:
1.
Remove two screws (item 20) and gear frame (item 8).
2.
Remove the gear cluster (item 16), washer (item 17), and shaft (item 15).
3.
Remove the drive gear (item 14) and washers (item 12) by rotating and pulling the drive gear.
4.
Remove the O-ring seal (item 13).
NOTICE
When reassembling seal, lubricate O-ring with oil or petroleum jelly and replace in cover.
Place washer on drive gear shaft. Carefully rotate and push shaft through O-ring and
cover to prevent damage to O-ring. Shaft must also be guided into pinion bevel (item
18) if counter has not been removed. Replace remaining parts to complete assembly by
reversing disassembly procedure.