ACTION
WHAT/WHO
Instruct
New operator
Check
High pressure hose
Check
Pressure gauge
Check
Detergent suction
Clean
Water filter
Clean
Fine sand filter
Check
Machine for leaks
Adjust
Oil burner
Clean
Boiler/coil
Perform
Descaling
Check
Thermostat
Symptoms
High pressure cleaner
does not start.
High pressure cleaner
stops suddenly.
Motor hums when
started.
High pressure hose and
pistol shake.
32
CHECK LIST
WHEN/HOW OFTEN
Before operator uses high pressure cleaner
During daily use
During daily use
Daily - by means of detergent
Weekly/as needed
As needed
Every other month
Twice a year/ as needed
Yearly/as needed
For pressure increase over 5 bar
Every other month
FAULT FINDING
Cause
Switch not activated.
High pressure cleaner not
connected to the power.
Fuse burnt out.
Missing voltage in plug.
Fuse burnt out.
Low voltage.
Motor or coil too warm.
Operating pressure too high (nozzle dirty).
Fuse burnt out.
Fault on the power line.
Air in the pump.
Detergent valve open.
Lack of water.
HOW
Let operator read instruction guide
Leaks ? - call service engineer
Too high/too low ? - call service engineer
Lack of suction/leaks ? - call service engineer
See maintenance
See maintenance
Leaks ? - call service engineer
Call service engineer
Call service engineer
See maintenance
Temperature too high/low ?
- call service engineer
Corrective action
Activate switch.
Put in the plug, switch on the mains switch.
Change fuse. If fuse burns out again,
contact service department.
Connect voltage according to el. diagram.
Change fuse. If fuse burns out again,
contact service department.
Extension cable too long, contact service department.
Set switch in pos. "0" and wait 15 min. Restart the
machine.
Clean/change nozzle (see technical data).
Change fuse. If fuse burns out again or motor still
hums, contact service department.
Check voltage in the plug.
Tighten suction hose.
Turn the detergent regulation to pos. "0".
Clean suction filter. Open tap completely.