Descargar Imprimir esta página

IPC GE 20 Manual De Instrucciones página 15

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
Before using the space heater, please read carefully all the instructions for use described below and follow the
indications scrupulously.
The manufacturer cannot be held responsible for damage to persons and/or property caused by improper use of
the equipment.
This instruction manual is an integral part of the equipment and must therefore be kept carefully and passed on
with the unit in the event of a change of ownership.
GENERAL RECOMMENDATIONS
Heaters run on fuel oil or kerosene.
They generate hot air mixed with combustion gases.
Always follow local regulations and laws when using this heater.
• read and follow this owner's manual before using the heater.
• use only in places free of flammable vapours or high dust
content.
• never use heater in immediate proximity of flammable
materials. Minimum clearance 2,50 m.
• make sure fire fighting equipment is readily available.
• Ensure that the machine resting surface or ground is not made
of flammable material;
• make sure sufficient fresh outside air is provided according to
the heater requirements. They should only be used in well
ventilated areas in order to avoid carbon monoxide poisoning.
• never block air inlet (rear) or air outlet (front).
• in case of very low temperatures add kerosene to the heating
oil.
• make sure heater is always under surveillance and keep
children and animals away from it.
• before starting the heater always check free rotation of
ventilator.
• unplug heater when not in use.
SAFETY DEVICES
The heater is fit with an electronic device that controls the
flame and the maximum safe temperature by means of a
photocell and an overheat thermostat.
The electronic device controls start/stop times and trips the
safety in case of malfunctions. It has reset button (13) that can
assume different colours (Function Light) depending on the
function mode:
• off: heater is in idle mode or in "stand-by" mode, waiting for
heating request;
• steady green: heater functioning normally;
• steady red: heater in safety stop;
• flashing orange: heating interrupted due to excessive
variations in voltage supply (T<165V or T>280V); heating will
resume automatically when voltage returns in range from 180
V and 275 V.
Warning
To restart heating after a safety stop, push reset
button (13) for 2 seconds.
Warning
NEVER do more than two restarts in a row:
uncombusted diesel fuel may accumulate in the
combustion chamber and suddenly flare up at the
next restart.
If the safety stop persists, you have to find and eliminate the
cause of the stop before you restart the heater.
OPERATION
Before any attempt of starting the heater is made, check that
your electrical supply conforms to the data on the model plate.
EN
IMPORTANT
Warning
Mains must be fitted with a thermo-magnetic
differential switch.
Unit plug must be linked to a socket with a mains
switch.
The heater can run automatically when connected to a control
device such as thermostat, time clock. Connect the controller
cable with a clamp to be inserted into hole (16) according to
wiring diagram on page 19. Follow the instructions provided with
the thermostat.
To start heater, connect to mains, set control device at desired
value, set switch (14) on position
immediately followed by ignition. When unit is started for the first
time or is started after the oil tank has been totally emptied, the
flow of oil to the burner may be impaired by air in the circuit. In
this case the control box will cut out the heater and it might be
necessary to renew the starting procedure once or twice by
pressing button (14) in position "0" and pressing the button in the
position
.
If the heater does not start, check that oil tank contains fuel.
Press the button on position "0" and restat the space heater
pressing the button on position
If the heater still does not work, please refer to chapter
"TROUBLESHOOTING, CAUSES AND REMEDIES".
Warning
If the voltage supply is less than 190 V, the space
heater automatically stops and the lamp flashes.
The space heater can automatically restart when
the voltage goes up again to 205 V.
When there is no more fuel in the tank, the heater automatically
stops and re-arm button (15) lights up (red).
After refilling the tank, re-arm button (15) to restart the heater.
Warning
You may need two or more attempts to restart the
heater.
All air must be eliminated from the fuel circuit so
that the circuit can be completely filled with fuel.
STOPPING THE HEATER
Set main switch (14) on "0" position or turn thermostat or other
control device on lowest setting. Flames shut off while fan is
cooling
off
postventilation time.
TRANSPORT
Warning
Before heater is moved:
• stop the heater following instruction "STOPPING
THE HEATER";
• unplug the heater;
• wait until combustion chamber has been
completely cooled off.
13
: the ventilator starts,
.
the
combustion
chamber
for
the
pre-set

Publicidad

loading

Este manual también es adecuado para:

Ge 20 pt162600