3
Operation
3.1
Indoor unit overview
Key to figure 1:
[1]
Top panel
[2]
Space for small filter (optional)
[3]
Air filter
[4]
Back of the display
[5]
Button for manual operation
[6]
Airflow panel
Indoor unit display
Symbol Explanation
Number Temperature display
Displayed with some functions, if these are switched on.
Indicates that the ON timer is active when the indoor unit is
switched off.
0F
Displayed with some functions, if these are switched off.
dF
Automatic defrosting active
FP
Frost protection active: the indoor unit keeps the room
temperature at a minimum of 8 °C.
CL
The self-cleaning function is active
Ex, Px,
Fault code ("x" stands for any digit).
Fx
Table 32 Symbols in the display
3.2
Remote control overview
Keys on remote control
1
2
3
Pos. Key
Function
K
1
Switch on/off.
Mode
Set operating mode.
ECO function
2
SET
Select advanced operating functions.
OK
Confirm choice.
Set timer.
.
Increase temperature.
/
Reduce temperature.
Climate 2000 – 6721852026 (2023/05)
Pos. Key
3
Swing
Turbo
LED
Clean
Table 33 Keys on remote control
Display of remote control
1
2
0010044707-001
3
4
Pos. Symbol Explanation
1
2
3
0010037628-002
4
Table 34 Symbols in the display
Function
Fan step
Set swing function.
Restore function: restore previous setting.
Turbo cool/Turbo heat
Switch off display of indoor unit and alarm buzzer
(Mute Mode).
Self-cleaning
Infographic: self-cleaning is active.
Operating function: Sleep mode is active.
Operating function: Follow Me function is active
(Follow Me); temperature measurement at the
remote control.
Infographic: battery status
Operating mode: automatic mode
Operating mode: cooling mode
Operating mode: dehumidification mode
Operating mode: heating mode
Operating mode: Fan Mode
Value display: shows the set temperature, fan speed
or (when timer is activated) the timer setting as
standard.
Infographic: transmission indicator; lights up when
the remote control sends a signal to the indoor unit.
Infographic: energy saving function active.
Infographic: ON/OFF timer active.
Value display: shows the current fan speed. There are
several output stages (bars) and the AUTO setting for
automatic control
Infographic: automatic vertical swing function active.
(up/down).
Infographic: Turbo cool/Turbo heat is active.
Operation
0010037630-002
23