Descargar Imprimir esta página

Bosch Climate 2000 Manual De Servicio Para El Usuario página 25

Ocultar thumbs Ver también para Climate 2000:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
▶ Press the Mode and Swing keys simultaneously for one second when
the device is switched off.
▶ To exit the cleaning position: press and hold both keys again.
3.6.2
Changing over display and alarm buzzer (Mute Mode)
▶ To switch on or off the display at the indoor unit and the alarm buzzer:
press LED key.
▶ To display the current room temperature, press the LED key and hold
for 5 seconds.
▶ To display the set temperature: press and hold the LED key for
another 5 seconds.
3.6.3
Noise reduction (Silent Mode)
This function reduces the noises emitted by the indoor and outdoor unit
when it is in operation. This is particularly advantageous at night, if you
need to show consideration for your neighbours.
▶ During operation, press the
Exiting the function:
▶ Press the
key again for 2 seconds.
-or-
▶ Press the K key, Mode key, Turbo key or Clean key.
When the outdoor unit is in quiet mode, it may not be possible to achieve
the required cooling/heating capacity because the compressor operates
at a low frequency.
3.6.4
Restore function
The indoor unit notes the current and previous setting, for e.g. operation
mode, temperature and fan speed. The restore function can switch
between the previous and current setting.
▶ Press the
key to switch to the previous setting.
▶ Hold the
key pressed for longer than two seconds to switch to the
current setting.
3.6.5
Turbo cool/Turbo heat
When Turbo cool/Turbo heat is active, the indoor unit operates at
maximum power to heat or cool the room quickly.
▶ Turbo cool: switch on Cooling mode and press the Turbo key.
▶ Turbo heat: switch on heating mode and press the Turbo key.
Exiting the function:
▶ Press the Turbo key again.
3.6.6
Self-cleaning
The device has a self-cleaning function for the evaporator. The self-
cleaning freezes dust, mould and grease. Everything is then quickly
defrosted and dried with hot air.
▶ To activate the self-cleaning: press the Clean key.
CL appears on the display of the indoor unit when self-cleaning is in
progress. Self-cleaning ends automatically after 20 to 45 minutes.
3.6.7
Frost protection (8 °C Heating)
The frost protection can be activated to keep the room temperature at a
minimum of 8 °C.
4.2
Faults not indicated
If faults occur during operation that cannot be eliminated:
▶ Call customer service about the fault, providing details of the device.
Fault
The output of the indoor unit is too low.
Climate 2000 – 6721852026 (2023/05)
key for 2 seconds.
Possible cause
Temperature is set too high or too low.
Air filter is soiled and must be cleaned.
Unfavourable ambient conditions for the indoor unit, e.g. the ventilation openings of the devices are
obstructed, doors/windows in the room are open or the room contains powerful heat sources.
Low-noise operation is activated and prevents the full output from being used.
▶ In heating mode, press the / key 2x within 1 second.
The unit remains off until the temperature falls below 8 °C.
Exiting the function:
▶ Press the K key, Mode key, Turbo key or Clean key.
3.6.8
Sleep mode
The purpose of this function is to save energy during idle times. After an
hour, the device heats or cools less intensely. To do this, the set
temperature is changed by 1 °C. After two hours, the set temperature
changes by a further 1 °C. Then it remains at the new temperature.
▶ Press the Set key and . or / keys to select the function.
The function is not available in dehumidification mode and Fan Mode.
3.6.9
Key lock function
The keys of the remote control can be locked with the keylock.
▶ To switch the keylock on/off: press the Clean and Turbo keys
simultaneously for 5 seconds.
The symbol
appears in the display when the keylock is active.
3.6.10 Advanced operating functions
▶ Press the Set key.
▶ Press the Set key or ., / keys to select the function.
= Follow Me function
▶ Confirm selection with the OK key.
Exiting the function:
▶ Repeat the above steps.
Follow me function (Follow Me)
The function activates the remote control at the current location in order
to measure the temperature at 3-- minute - intervals. The indoor unit is
now controlled with reference to these measurements.
The Follow Me function is only available in cooling mode, heating mode
and automatic mode.
4
Troubleshooting
4.1
Faults with indication (Self diagnosis function)
If a fault occurs during operation, the LEDs flash for an extended period
or an error code is displayed (e.g. EH 02).
If a fault is present for more than 10 minutes:
▶ Briefly disconnect the power supply and switch the indoor unit back
on.
If a fault persists:
▶ Call customer service and provide the fault code and details of the
appliance.
Troubleshooting
25

Publicidad

loading

Este manual también es adecuado para:

Cl2000u w 26 eCl2000u w 35 eCl2000u w 53 eCl2000u w 70 eCl2000 26 eCl2000 35 e ... Mostrar todo