Space Requirement
■ Keep enough space for the door to open. See Figure 1.
IMPORTANT! Ensure that there is adequate air circulation around the appliance and
at least a 50mm gap on all sides. A lack of air circulation leads to overheating.
Location
■ Install the appliance in a location with an ambient temperature corresponding to
the climate class indicated on the rating plate of the appliance:
Climate Class
Extended temperate
Temperate
Subtropical
Tropical
■ This freezer is not intended to be used as a built-in appliance.
■ The appliance should be installed far away from sources of heat such as radiators,
boilers and direct sunlight. Ensure that air can circulate freely around the back
of the appliance. Ideally, the appliance should not be positioned below any
overhanging wall units. However, if it is placed under an overhanging wall unit,
make sure there is a clearance distance of at least 50 mm. Do not stack the
appliance with other household appliances.
■ Accurate levelling is ensured by one or more adjustable feet at the base of the
appliance.
■ This appliance is not intended to be used as a built-in appliance.
Electrical Connection
■ Before plugging the appliance in, ensure that the voltage and frequency shown
on the rating plate corresponds with your domestic power supply. The appliance
must be grounded/earthed. The power supply cord plug is provided with a
contact for this purpose. If the domestic power supply socket is not grounded,
connect the appliance to a separate earth in compliance with current regulations.
Consult a qualified electrician.
F
F
Ambient Temperature Range
SN
10° C to 32° C
N
16° C to 32° C
ST
16° C to 38° C
T
16° C to 43° C
9
A
0
B
0
C
1420
D min= 0
F
E
min=50
F
min=50
G
960
H
1130
I
135°