12-21
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
− Apply the solder directly at the soldering point, not on the
soldering tip.
− Change the soldering tip using an appropriate tool.
− Do not subject the soldering tip to physical force.
Note
The control units have been adapted to hold a medium-sized
soldering tip. Discrepancies may occur if the tip is changed or a
different shaped tip is used.
7 Setting parameters via the parameter
menu
The parameter menu is subdivided into two areas:
Parameter
Setting options:
- Standby temperature
- Standby time (temperature deactivation)
- AUTO OFF time (automatic switch-off time)
- Offset (temperature offset)
- Control response
- Process window
Station parameters
Setting options:
- Language
- Temperature version °C/°F (temperature units)
- Password (lock function)
- Touchtones on/off
- LCD contrast
- LCD background brightness
- Screen saver
- Robot output
- Vacuum pre-feed
- Vacuum run-on
7.1
Set parameters
Please observe the overview diagrams (Fig. 1 and Fig. 2).
Setting the standby temperature
Note The soldering tools have a usage detector (sensor) in the handle
which automatically starts the cooling cycle when the soldering tool
is not in use.
You will find further information about the intelligent tool in the
relevant operating instructions.
WXD 2