Descargar Imprimir esta página

Allen + Roth VFL3-RO24DRL Manual Del Usuario página 39

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
PROBLEM
White powder resi-
due forming within
burner box or on
adjacent walls or
furniture.
Heater produces
unwanted odors.
Heater shuts off in
use (ODS operates).
Gas odor exists
even when control
knob is in OFF posi-
tion.
Moisture/conden-
sation noticed on
windows.
Slight smoke or odor
during initial opera-
tion
Heater produces a
whistling noise when
burner is lit.
POSSIBLE CAUSE
1. When heated, the vapors
from furniture polish, wax,
carpet cleaners, etc., turn into
white powder residue.
1. Heater is burning vapors
from paint, hair spray, glues,
etc. See IMPORTANT
statement, page 26.
2. Gas leak. See Warning
Statement, page 26.
3. Low fuel supply.
1. Not enough fresh air is
available.
2. Low line pressure.
3. ODS/pilot is partially
clogged.
1. Gas leak. See Warning
Statement at top of page 26.
2. Control valve is
defective.
1. Not enough combustion/
ventilation air.
1. Residues from
manufacturing process.
. Turning control knob to high (5)
position when burner is cold.
2. Air in gas line.
3. Air passageways on
heater are blocked.
4. Dirty or partially clogged
burner orifice.
CORRECTIVE ACTION
1. Turn heater off when using furniture
polish, wax, carpet cleaner or similar
products.
1. Ventilate room. Stop using odor
causing products while heater is running.
2. Locate and correct all leaks (see
"Checking Gas Connections," page 20).
3. Refill supply tank (Propane /LP models).
1. Open window and/or door for
ventilation.
2. Contact local gas supplier.
3. Clean ODS/pilot (see Care and
Maintenance, page 34 - 36).
1. Locate and correct all leaks (see
"Checking Gas Connections", page 20).
2. Contact customer service.
1. Refer to "Air for Combustion and
Ventilation" requirements, page 8.
1. Problem will stop after a few hours of
operation.
1. Turn control knob to low (1) position and
let warm up for a minute.
2. Operate burner until air is removed from
line. Have gas line checked by local
propane/LP gas company.
3. Observe minimum installation
clearances (Fig. 3,4,5,7 & 8 page
12 - 15).
4. Clean burner (see Care and Maintenance,
page 34 - 36) or contact customer service.
39