ENGLISH
Pump blocked or out of order.
− see above.
Hydromat incorrectly adjusted, fault
indicator lamp is on.
− Check cut-in pressure, readjust if
necessary.
8.2
Hydromat adjustment
When the cut-in pressure is too high and
the fault indicator lamp (11) is on, the
Hydromat needs to be readjusted.
11
1.
Unplug.
2.
Turn the regulating screw (12) as
follows:
− counter-clockwise to decrease
the cut-in pressure;
− clockwise to increase the cut-in
pressure.
3.
Start equipment again and check
function (see "Operation").
9. Repairs
A
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
For shipping:
Drain pump completely (see "Equip-
ment dismounting and storing").
Dismount Hydromat (to prevent
shipping damage).
Ship equipment in original packing,
if possible.
10. Environmental Protection
The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
14
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
11. Available Accessories
For this equipment the following acces-
sories are available at specialist dealers.
3
Note:
Illustrations and stock numbers
can be found at the end of these instruc-
tions.
A
Pump Installation Package,
complete with double nipple, check
valve, filter short, washable filter
cartridge, spiral hose assembly
12
1 m, thread sealing tape.
B
Hydrostop,
for automatic stopping when there
is a lack of water, prevents the
pump from running dry.
C
Dry-running Stop Switch,
with 10 m cable, keeps the pump
from running dry when pumping
from tank, pool, etc.
D
Spiral Hose 1"
1) 1 m
assembly,
release screw fitting at both
ends;
2) 4 m,
complete
release
strainer with foot valve;
3) 7 m,
complete
release
strainer with foot valve.
E
Filter, 1" connection, short,
complete with washable plastic fil-
ter cartridge.
F
Disposable Filter Cartridge, short,
for mechanical preliminary filtering
of sand.
G
Washable Filter cartridge, short,
for mechanical preliminary filtering
of sand, reusable.
H
Activated Carbon Filter Cartridge,
short,
for
use
with
removes odours or discolouring.
I
Filter Cartridge Poly, short,
filled with polyphosphate, for calcif-
erous water supplied to water heat-
ers.
J
Pipe Nipple 150 mm, 1" male at
both ends, galvanized, to connect
pump and filter.
K
Double Nipple, 1" male at boths
ends.
L
Check Valve 1" female, prevents
water backflow and pump running
dry.
M
Thread Sealing Tape, 12 m roll.
with
quick
with
quick
screw
fitting
and
with
quick
screw
fitting
and
chlorous
water,