BR N
CBX1 SERIES
Page 5
7" ROUND
KNOCKOUT
PLATE (also
remove 3W' x 10"
vertical plate)
r')
_
314'' X 10"
VERTICAL
KNOCKOUT
314'' X 10"
PLATE
KNOCKOUT
PLATE
INSTALL
THE HOOD
_
ARNING
To reduce the risk of electrical shock, switch power off
at service panel. Lock or tag service panel to prevent
power from being switched on accidentally.
[_
DUCTED INSTALLATION
ONLY:
Remove 314'' x 10 vertical, 314'' x 10" horizontal, or 7-inch
round knockout
plate(s) as appropriate for your ducting
method.
[_
Remove Electrical
Power Cable Knockout from top or
back of hood.
7" ROUND
DUCT
PLATE
DUCTED INSTALLATION
ONLY:
Attach 31,4 '' × 10" Damper/Duct
Connector
(if using 314''
x 10" duct) or 7" Round Duct Plate (if using 7-inch round
duct) over the knockout opening.
Notes:
To accomodate
off-center ductwork, the 3X"x 10"
damper/duct
connector can be installed up to Y2"on either
side of the hood center and the 7" round duct plate can
be installed up to W' on either side of the hood center.
Install the 3W'x 10" Damper/Duct Connector with the
Damper Flap Pivot nearest the Top/Back Edge of
Hood.
HOUSE
POWER
CABLE
[_
Run House Power Cable between service
and hood
panel
location. Attach power cable to hood using appropriate clamp.
El
Hang hood from (4) mounting screws driven
into
part-way
cabinet locations (shown in illustrationsunder "PREPARE
HOOD LOCATION"). Mounting screws are includedin parts
bag. Slide hood back towards wall until mounting screw
heads are engaged in narrow end of keyhole slots in top of
hood. Tighten screws securely. Add 5th mounting screw in
center hole in hood and tighten securely.
DUCTED INSTALLATION ONLY:
Connect ductwork to hood and use duct tape to make joints
secure and air-tight. Make sure the damper/duct
connector
enters the ductwork and that the damper opens and closes
freely.