The ash grate is made of grey cast iron (RIVER LINE), in 5mm-plates (NEW LINE);
Heat-resistant ceramic glass. Can withstand temperatures of up to 750°C in continuous use;
Heat-resistant paint for temperature peaks up to 900°C and operating temperatures around 600°C.

Unit Assembly

Raise the upper lid of the unit and remove the casing from the inside (River Line);
Insert the ash grate into the unit, into the hole at the bottom of the unit;
Attach the appropriate hinges to the glass door, at the unit front;
Attach the handles to the upper lid and to the unit drawer (River Line);
Secure the baffle plate to the feet inside the unit, to their highest slanted side.
In the case of the model New Line Cube Box, to remove the stove from the pallet you should unscrew the 4 screws with a
Philips PH2 key (following figure).
Note
: The assembly of the RIVER LINE unit requires a screwdriver. The door and the upper lid and drawer handles are shipped inside
the casing at the upper part of the unit.

Installation

Attach the throat to the unit smoke outlet;
At the smoke outlet, make sure that the throat has the diameter size specified in the above table of this guide and that no
shrinkage or blockage occurs;
Attach the tube to the upper part of the throat next to the smoke outlet;
Sequentially place the required tubes at their upper part ensuring the pipe has the proper height;
Attach each of the tubes to one another and secure them to the flue or to the outer wall, if appropriate;
To ensure a proper draught, use at least 2m of stainless steel flue tube (no curves), sealed to the masonry parts;
After this section, sections of tubing with maximum angle of 45º may be used. It is recommended that the installation is as
vertical as possible;
If the unit is to be installed in an existing masonry fireplace, it is recommended that the tubes are long enough to reach the
exterior air outlet; if the smoke outlet uses tubes only, these shall be at least 3 linear meters long;
Both the flue tube and the unit must be away from any combustible material. The use of a double-walled, insulated tube is
recommended;
The flue should allow for good air circulation and be placed at least 60cm above the top of any obstacle located within a
distance of 3m. Do not connect this unit to a flue serving another appliance;
The unit should stand on a hearth made of refractory bricks with a load capacity sufficient to support it;