Descargar Imprimir esta página

EdilKamin Gsm Dialler Manual De Instrucciones página 76

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
8.4
TEST manual switching on/off of all the outputs
You can manually activate all of the LX-GSM-01 dialler outputs in order to carry out a functional
test.
For this purpose activate microswitch No. 2 in the ON position and restore it to the OFF position
at the end of the test.
The same test can be carried out by sending the SMS text message ALL ON to activate all the
outputs and ALL OFF to deactivate them.
9. LX-GSM-01 dialler inputs status detection
9.1
Remote environment probe SA temperature reading
Request SMS text message
SA
Reads the temperature of the probe (optional) connected to the SA input
9.2
Temperature reading from TB probe inside dialler
Request SMS text message
TB
Reads the temperature of the probe connected inside the LX-GSM-01 dialler
9.3
IN 1 input status detection
Request SMS text message
IN 1
IN 1
Detects the status of the IN 1 input and notifies if the automatic input control alarm service is
enabled or disabled (SMS IN 2 DISABLED or ENABLED) see section 10.1
9.4
IN 2 input status detection
Request SMS text message
IN 2
IN 2
Detects the status of the IN 2 input and notifies if the automatic input control alarm service is
enabled or disabled (SMS IN 2 DISABLED or ENABLED) see section 10.2
ON
1 2 3 4
SMS text message reply SA temperature °C
SMS text message reply TB temperature °C
Possible SMS text message
reply
IN AUX 1 OFF
IN AUX 1 ON
Possible SMS text message
reply
IN AUX 2 OFF
IN AUX 2 ON
- 76
-
SA Temp = 20
TB Temp = 40
STATUS
Input open
Input closed
STATUS
Input open
Input closed

Publicidad

loading