Descargar Imprimir esta página

Thermador Professional PRO-HARMONY An American Icon PRD30 Manual De Instalación página 17

Estufas de todo tipo de gas

Publicidad

Idiomas disponibles

Idiomas disponibles

<4 Upper Nut
©)
GAY Cupped Washer
<4 Supply Wire
Flat Washer
Figure 12:
Conductor Securement
3-CONDUCTOR
CORD — WHERE
LOCAL CODES
AND ORDINANCES
PERMIT GROUNDING
THROUGH
NEUTRAL, AND CONVERSION
OF
SUPPLY TO 4 WIRE IS IMPRACTICAL,
UNIT MAY
BE CONNECTED
TO THE POWER
SUPPLY WITH A
3-POLE, 3-CONDUCTOR CORD
KIT RATED 125/250
VOLTS, 50 AMPERES, AND MARKED
FOR USE
WITH RANGES. The cord kit must be attached to the
range junction box with a strain relief which will fit a 1"
diameter hole. If not already equipped, the cord must
have 1/4" faston closed-loop lugs attached to the free
ends of the individual conductors, prefer-ably soldered
in place.
Installer — show the owner the location of the circuit
breaker or fuse. Mark it for easy reference.
A 3- or 4-conductor supply may be connected to the
terminal block.
3-Wire Lead Connection
1.
Remove upper nuts only from the terminal block studs.
Do not remove nuts which secure range internal
wiring leads.
Secure the neutral, grounded wire of the supply circuit,
to the center stud of the terminal block with nut. (See
Figure 13).
Secure the L1 (black) and L2 (red) power leads to the
outside terminal block studs (brass colored) with nuts.
4.
Tighten nuts securely.
Neutral
White
L1 Black®
Figure 13:
3 Wire Connection
4-Wire Connection
1.
Remove upper nuts only from the terminal block studs.
Do not remove lower nuts which secure range
internal wiring leads.
Remove ground strap screw and bend the strap up as
shown in Figure 14.
Secure the neutral wire to the center stud of the
terminal block with nut.
Secure the L1 (black) and L2 (red) power leads to the
outside terminal studs (brass colored) with nuts.
Secure the bare copper ground lead to the range
chassis using the ground screw previously used for the
ground strap. Be sure that neutral and ground
terminals do not touch.
Tighten all connections securely.
S
.
A
Bend Ground Strap U
p
Figure 14:
Ground Strap
English 15

Publicidad

loading