Descargar Imprimir esta página

ALFRA TMA 600 A Manual De Instrucciones página 17

Ángulo de soldadura variable

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

deTAiLed PeRFoRMAnce dATA FoR The SwiTchAbLe MAgneTic
cLAMP TMc 300
Values shown for the performance of the TMC 300 are based on measurements made on material S235 JR,
comparable to AISI 1020 Cold Rolled Steel, for the maximum, vertical breakaway force at 0° deviation from
the load axis and additionally under a 90° inclined load. These values do not include any safety factor. The
magnetic clamp will detach itself abruptly when the load exceeds values given in table 2.
Table 2
Thickness of material
mm
2
3
4
5
>6
Thickness of material
inches
0,08
0,12
0,16
0,20
>0,25
During each application, watch for any deformation of the work piece that might occur. If an air gap forms
between the magnetic surface and the work piece, the magnetic clamp will not reach the stated holding
force and could detach itself. Please check for any air gap developing at the edges of the TiN-coated
magnetic surface if necessary (e.g. with a sheet of paper; 80g/m
Breakaway force in kg
Clean, flat,
ground surface
Air gap <0.1 mm
90°
90
30
150
50
240
80
285
95
300
100
Breakaway force in lbs
Clean, flat,
ground surface
Air gap <0.004 inches
90°
198
66
330
110
540
180
630
210
660
220
immediately stop the operation if there is any excessive
!
deformation of the work piece or if an air gap occurs.
never exceed the dimensions and/or the load-bearing
!
capacity of the material thickness given in table 2.
Rusty, slightly scratched
surface
Air gap = 0.25 mm
90°
75
25
120
40
180
60
210
70
210
70
Rusty, slightly scratched
surface
Air gap = 0.01 inches
90°
165
55
270
90
390
130
465
155
465
155
).
2
Irregular, rusty or rough
surface
Air gap = 0.5 mm
90°
66
22
105
35
135
45
150
50
150
50
Irregular, rusty or rough
surface
Air gap = 0.02 inches
90°
150
50
225
75
300
100
330
110
330
110
17