Provide
an adequate
Gas Supply
When shipped from the factory, this unit is designed to
operate on 4"(10,16
cm) water column (1.0 kPa) Natural
gas manifold pressure. A convertible pressure regulator is
connected to the range manifold and MUST be
connected in series with the gas supply line. If LP/
Propane conversion kit has been used, follow instructions
provided with the kit for converting the pressure
regulator to LP/Propane use.
Care must be taken during installation of range not to
obstruct the flow of combustion and ventilation air.
Forproper
operation, the maximum inlet pressure to the
regulator should be no more than 14"(35,S6 cm) of
water column pressure (3.5 kPa). The inlet pressure to
the regulator must be at least 1 " (.25 kPa) greater than
the regulator manifold pressure setting. Examples: If
regulator is set for natural gas 4" (10,16 cm) manifold
pressure, inlet pressure must be at least 5"(12.60 cm); if
regulator has been converted for LP/Propane gas
10"(25,4 cm) manifold pressure, inlet pressure must be
at least 11 "(27,9 cm).
Connection
to Pressure
ReguJator
The regulator is already installed on the appliance.
Do not make the connection too tight.
The regulator is die cast. Overtightening
may crack the
regulator resulting in a gas leak and possible fire or
explosion.
Manual
GAS FLOW
Pressure
Shutoff
Flare
_
Flare
Regulator
Valve
Union
Union
On,
t
t
t
Nipple
Flexible
Nipple Access
Off
Connector
Cap
All connections must be wrench-tightened
Figure 5
Leak testing of the appliance shall be conducted
according to the instructions in step 4.
The gas supply line should be Y2" or sA" I.D. (Interior
Diameter)
Seal the
openings
Seal any openings in the wall behind the range and in the
floor under the range after gas supply line is installed.
Connect the range to the gas suppJy
Important:
Remove all packing material and
literature from range before connecting gas and
electrical supply.
To prevent leaks, put pipe joint sealant on all external
pipe threads.
Your regulator is in location shown below.
Do not
allow
regulator
to
rotate
on pipe
when
tightening
fittings.
Assemble the flexible connector from the gas supply pipe
to the pressure regulator in the following order:
1. manual shutoff valve (not included)
2. I/2"
nipple (not included)
3. 1/2" flare union adapter (not included)
4. flexible connector
(not included)
5. 1/2" flare union adapter (not included)
6. I/2"
nipple (not included)
7. pressure regulator
(included)
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections.
If flexible
connectors are used, be certain connectors are not
kinked.
The supply line must be equipped with an approved
manual shutoff valve. This valve should be located in the
same room as the range and should be in a location that
allows ease of opening and closing. Do not block access
to the shutoff valve. The valve is for turning on or
shutting off gas to the appliance.
t_
PRESSURE REGULATOR
LOCATION
Figure 4
Shutoff
Valve =
Open
position
Figure 6