3.
TECHNICAL
SPECIFICATIONS
Call Forwarding device for 4+N
External input voltage: .............................. 24 V
Maximum absorption: .............................. 200 mA
Absorbed power in operation: ................ max 6 W
Operating temperature: ........................ -5 ÷ +45° C
Max humidity: ............................................ 95% RH
Ethernet interface: ............................. 10/100 Mbps
Wi-Fi: ......................................................... 2.4GHz
(conforms to IEEE 802.11 b/g/n)
Dimensions (LxHxD):
140 (~8 DIN modules) x 90 x 60 mm.
Frequency band: ..................... 2400 ÷ 2483,5 MHz
Output power (Max): ................................... 20 dBm
The product is designed to be
powered by external power supply
Ref. 1083/24 via 24V (6 W, 24 V
terminals, with power supply up to the
specified power source requirements
(LPS) and protected against short
circuits and overcurrents according
to EN 60950-1:2006+A11+A1+A12+A2
provisions.
Power supply (provided)
Power supply: .................... 100-240 Vac 50/60 Hz
Power: .................................................. 12 W max
Secondary output: ........................ 24 V
Power dissipated after after 1 hour of functioning:
Dimensions (WxHxD):
36 (2 DIN modules) x 98 x 60 mm
3.1. KEY TO SYMBOLS
Symbol
safety-critical components
DS9854-005D
with internal antenna
max 11 Wh (~40 KJ)
Description
Direct input voltage
DANGER - Presence of
4.
SIMPLIFIED EU
DECLARATION OF
CONFORMITY
Hereby, URMET S.p.A. declares that the radio
equipment type:
Call Forwarding Device for 4+N Ref. 9854/58
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is
available at the following internet address:
www.urmet.com
)
0,42A
For more information scan the QR Code below with
your smartphone or tablet:
http://qrcode.urmet.com/default.aspx?pagUrmet=
sbu2CallForwarding