LED INDICATORS:
Light steady on: board powered in NON LOW ENERGY function
Triple flash: board powered in LOW-ENERGY function
POWER
Flashing alternating with ADV LED: logic and parameters pro-
gramming via U-Link
Flashing alternating with POWER LED: logic and parameters pro-
ADV
gramming via U-Link
IC1
Lit: IC1 input activated
STOP
Unlit: STOP input activated
SAFE 1
Unlit: SAFE 1 photocell input activated
Lit: the limitswitch closing of motor 1 is free
SWC1
Unlit: motor 1 closing limit switch input activated
Lit: the limitswitch opening of motor 1 is free
SWO1
Unlit: motor 1 opening limit switch input activated
Lit: the limitswitch closing of motor 2 is free
SWC2
Unlit: motor 2 closing limit switch input activated
Lit: the limitswitch opening of motor 2 is free
SWO2
Unlit: motor 2 opening limit switch input activated
Unlit: no error
ERR
LIT: see error diagnostics table
Unlit: remote programming not active
Radio LED only flashing: Remote programming active, waiting for
RADIO
hidden key.
(GRE-
Flashing in sync with Set LED: Transmitter deletion in progress
EN)
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset in progress
Fast flashing 10s: Autoset failed
SET
Flashing in sync with Radio LED: Transmitter deletion in progress
Lit 1s: Start/Stop after key S3 pressed
Lit 10s: Autoset completed correctly
9) ADJUSTMENT PROCEDURE
- Before turning the unit on, check electrical connections.
- Set the following parameters: Automatic Closing Time, motor force, slow-down
distance.
- Set the logics.
- Run the autoset function.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations)
10) INSTALLATION TEST PROCEDURE
1. Run the AUTOSET cycle (*)
2. Check the impact forces: if they fall within the limits (**) skip to point 9 of the
procedure, otherwise
3. Where necessary, adjust the sensitivity (force) parameter: see parameters table.
4. Check the impact forces again: if they fall within the limits (**) skip to point 9
of the procedure, otherwise
5. Apply a shock absorber profile
6. Check the impact forces again: if they fall within the limits (**) skip to point 9
of the procedure, otherwise
7. Apply pressure-sensitive or electro-sensitive protective devices (such as a
safety edge) (**)
8. Check the impact forces again: if they fall within the limits (**) skip to point 9
of the procedure, otherwise
9. Make sure all devices designed to detect obstacles within the system's operating
range are working properly
(*) Before running the autoset function, make sure you have performed all the
assembly and make-safe operations correctly, as set out in the installation
warnings in the drive's manual.
(**)Based on the risk analysis, you may find it necessary to apply sensitive protective
devices anyway
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
INSTALLATION MANUAL
LED ERR:
Led SET
Led ERR
Lit
Slow flashing
Photocell test,
Reverse due to
Costa o Costa
obstacle - Am-
8k2 failed
Unlit
perostop
- Check photo-
- Check for ob-
cell connection
stacles in path
and/or logic
settings
Internal system
supervision
control error.
Lit
- Try switching
the board off
and back on
again.
If the problem
persists, contact
the technical
assistance
department.
Activation
the
board
Slow
devices: the ex-
flashing
pansion board is
Photocell test
activated (ADV
failed
DIP switch 2 set
to ON), check
- Check photo-
that the expan-
cell connection
sion board is
and/or logic
correctly
settings
nected.
the safety devi-
ces
to the expan-
sion board.
Fast flashing
Thermal cutout
- Allow automa-
ted device to
cool
Parameters and/
or Operating Lo-
gic edited
of
- If the "Slow-
expansion
down distance"
safety
is edited, run
a new Autoset
cycle to confirm
the new setting.
- If other para-
meters
and/or
operating logic
are edited, hold
con-
down S2 for 5s
Check
to confirm.
NOTE: In any
connected
case, the Au-
toset
function
confirms
all
changes made
to the board.
- 29
ZARA BT A80