Descargar Imprimir esta página

Uline H-3704 Manual Del Usuario página 3

Plataforma giratoria de alto perfil para película elástica

Publicidad

Idiomas disponibles

Idiomas disponibles

POWER AND CONTROL WIRING CHECKS
1. Using a voltage meter, check the AC voltage
coming to the system to insure proper voltage is
present.
2. Plug the power cord to a 120VAC outlet. Power
should be applied to the frequency drive and foot
switch.
OPERATING INSTRUCTIONS
1. Simply step on the foot pedal to start the turntable
drive motor. The foot pedal is a maintained switch.
Pressing the pedal again turns the turntable motor off.
Figure 2
RUN
PAGE 3 OF 24
SYSTEM SETUP CONTINUED
FREQUENCY DRIVE ADJUSTMENT
LED Indicators
Potentiometer
Up, Down and
Right/Left Keys
LED INDICATORS
STOP
FWD
REV
F
Lamp lights to indicate input frequency reference.
H
Lamp lights to indicate output Hz.
Lamp lights to indicate output amps.
A
U
Lamp lights to indicate user defined units.
TURNTABLE SPEED ADJUSTMENT
1. The turntable speed is adjusted by a built-in
potentiometer dial on the AC frequency drive.
Turn clockwise to increase, counter-clockwise to
decrease. The maximum turntable speed is 12 RPM.
START
STOP
RESET
ENTER
Green lamp lights during REV operation.
Green lamp lights during FWD operation.
Red lamp lights by pressing STOP.
Green lamp lights by pressing RUN.
LED Indicators
LED Display
Start Key
Stop Key
Enter Key
0721 IH-3704

Publicidad

loading