12 | English
Auto-Start remote
Rubber band length
Protection class
Data transfer
Bluetooth®
Bluetooth® 4.2 (Low
Frequency range
used
Output power
Energy supply Bluetooth® Low Energy mod-
ule
Coin cell
3 V lithium battery,
A) Without rubber band
Values can vary depending upon the product
and are subject to application and environ-
mental conditions. For further information
www.bosch-professional.com/wac.
Assembly and Operation
Mounting the Auto-Start Remote
– Attach one end of the rubber band (9) to
one of the two fastening hooks (8).
– Secure the Auto-Start remote (5) to the
cordless tool. To do so, tighten the rubber
band (9) and attach the free end to the
second fastening hook (8).
Cut the rubber band to the correct length,
as necessary.
Appropriate places are those at which the
cordless tool generates sufficient vibration
during operation. Never fasten the Auto-
Start remote to places which are required
to operate the cordless tool (such as grip-
ping surfaces, switches, displays).
1 609 92A 7U3 | (30.06.2023)
Starting operation
GCT 30-42
240 mm
Establishing a connection between
GCA 30-42 and GCT 30-42
IP54
– Ensure that the GCT 30-42 Auto-Start re-
mote is in the vicinity of the GCA 30-42 re-
ceiver.
Energy)
– Insert the mains plug of the dust extractor
into the mains socket.
2402–2480 MHz
– Set the switch of the dust extractor to
automatic start/stop.
< 10 mW
– Insert the plug (4) of the GCA 30-42
receiver (1) into the plug socket on the
dust extractor.
– The status indicator with the Auto-Start
CR 2032
symbol (2) flashes blue.
– Press the start/stop button (7) on the
GCT 30-42 Auto-Start remote until the
LED status indicator (6) has flashed blue
twice.
The LED status indicator (6) on the Auto-
Start remote GCT 30-42 briefly lights up
blue.
Connection established:
– The status indicator with the Auto-Start
symbol (2) on the GCA 30-42 receiver
lights up green.
– The LED status indicator (6) on the
GCA 30-42 Auto-Start remote briefly
lights up green.
When changing a coin cell, the following shall
apply:
– If the GCT 30-42 transmitter module was
connected to the GCA 30-42 receiver
module before changing the coin cell, the
connection is automatically re-established
after changing the coin cell.
Bosch Power Tools