Operating modes
Push
the navigation key to view the operating modes bar. Use the navigation key
again to select an operating mode, the framed icon
Push the
to activate the mode chosen.
Mode
selected
Comfort Manual Mode
The Comfort mode
selecting a value between 5°C and 30°C.
Select the mode by repeatedly pushing the navigation
to activate it. To set the reference temperature, push
the
and
keys.
Push again to
to confirm. The thermostat displays the measured temperature again.
In any case, after a delay of 10 seconds, the thermostat displays the ambient
temperature measured again.
The thermometer icon
shown in the screen is the ambient temperature. Use the set
key
If the heating icon is displayed, this indicates that the Comfort
temperature set is higher than the measured ambient temperature.
The radiator is therefore operating whereas, if it is not displayed,
the radiator is on but not operating.
Modes bar
makes it possible to set the temperature to be maintained, by
indicates that the temperature
to view the Comfort
17
indicates the mode selected.
key and push
and select it using
(the
icon disappears).