POWER OUT
Neutrik powerCON mains output socket for supplying power supply to additional CAMEO products.
Ensure that the total power consumption of all connected devices does not exceed the value
specified on the device in amperes (A).
4
ILDA IN
ILDA input with 25-pin D-sub connector for computer control. An ILDA interface and ILDA software
for show programming are not included with the device. The associated ILDA status LED lights
up as soon as an ILDA interface is connected to the ILDA IN input and the show laser is ready for
operation.
5
ILDA OUT
25-pin D-sub connector for transmitting the ILDA control signal.
6
KEY SWITCH ON / OFF
Lock switch for switching the built-in lasers on and off. The lasers are deactivated in the OFF
position and activated in the ON position. Two keys are included. In order to ensure the device
cannot be operated by unauthorised persons, lock the switch and remove the key!
7
INTERLOCK
The interlock connection allows for the implementation of an emergency cut-off sys-
tem that enables the immediate, remote-controlled shutdown of any connected effect
lasers in the event of a hazardous situation. Cameo LEYA lasers can only be operated
if the interlock circuit is closed. Pressing the emergency cut-off switch opens the
contact, thereby interrupting the circuit.
INPUT: Male 3-pin XLR socket for connecting the optionally available CAMEO emergency cut-off
switch; use a standard microphone or DMX cable to connect to the XLR socket of the switch. If the
emergency off switch is not used, the included bridging plug must be inserted into the interlock
socket in order to be able to activate the laser. The bridging plug is intended for service
purposes only and must not be used at events with an audience!
OUTPUT: Female 3-pin XLR connector for connecting compatible laser products to the Interlock
emergency cut-off system.
8
SCANFAIL MODE - BUTTON + INDICATOR LED ON / OFF
The ScanFail Safety system prevents the emission of a dangerous spot beam. Therefore, leave
the ScanFail Safety system permanently activated during operation! Only deactivate the Scan
Fail Safety system in exceptional cases (e.g. when adjusting the laser) and only if utmost care
has been taken to ensure that persons, animals and combustible materials cannot be hit by laser
beams (also take mirrors and other reflecting materials into consideration)!