ENGLISH
4.2
Mains connection
B
Danger! High voltage
Operate device in dry environ-
ment only.
Operate device only on a power
source complying with the following
requirements:
− outlets properly installed, earthed
and tested;
− fuse protection in accordance
with the technical specifications.
Position power cable so it does not
interfere with the work and is not
damaged.
Always check to see that the device is
switched OFF before plugging in.
Protect
power
cable
aggressive liquids and sharp edges.
Use only extension cables with suffi-
cient lead cross section (see "Techni-
cal Specifications").
Do not stop the compressor by
unplugging, but switch OFF using the
switch.
Unplug after use.
4.3
Generating compressed
air
1.
Start device (33) and wait until the
max. tank pressure is reached
(compressor shuts off).
The tank pressure is indicated by
the tank pressure gauge (37).
33
34
37
36
2.
Adjust pressure regulator (34) to
required working pressure. The cur-
rent working pressure is indicated by
the regulated pressure gauge (36).
12
A
Caution!
The regulated pressure must
not be set higher than the max. work-
ing pressure of the connected air
tools!
3.
Connect air hose to compressed air
outlet (35).
4.
Connect air tool.
32
You are now ready to work with the
air tool.
5.
Switch the compressor OFF, if you
do not continue working immediately
afterwards. Unplug after switching
OFF.
5. Care and maintenance
A
Danger!
Prior to all servicing:
− Switch Off.
− Unplug.
− Wait until the device has come to
a complete stop.
− Ensure the device and all air tools
and accessories connected to it
are relieved from pressure.
− Let the device and all air tools
and accessories used cool off.
After all servicing:
from
heat,
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the device.
Repair and maintenance work other
than described in this section must
be carried out by qualified specialists
only.
5.1
Periodic maintenance
Prior to each use
•
Check
replace if necessary.
•
Check all screwed connections for
tightness, tighten if necessary.
•
Check power supply cable for dam-
age, if necessary have replaced by
a qualified electrician.
Every 50 operating hours
•
Check air filter element (38) of com-
pressor pump, clean if necessary.
To do so, loosen screws of the
35
upper sound insulation hood and
remove hood.
air
hoses
for
damage,
38
•
Check oil level of pump with oil dip
stick (39), top up if necessary.
39
MAX
MIN
•
Drain condensate from pressure
vessel (40).
•
Clean air filter element (41) of filter/
regulator unit.
41
•
Drain condensate from filter/regula-
tor unit (42).
40
42