Descargar Imprimir esta página

GE 20" Wide Manual De Instrucciones página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

r_
3-WIRE INSTALLATION (GROUND ISTHROUGH THE NEUTRALWIRE)
AWARNING:
Shock
Hazard
The neutral
wire and ground
strap
must be
connected
as shown
below
for the range
to be
properly
grounded.
Do not remove
the ground
strap.
Failure
follow
this instruction
may result
in potential
shock
hazard.
Terminal
block
(appearance
may vary)
AWARNING:
Fire hazard
Neutral
Terminal
block screws
must be securely
tightened,
terminal
Failure
to do so may result
in potential
fire hazard.
FOR POWER CORD INSTALLATION
strap
A. Remove
the 3 lower screws
from the terminal
Ground
block.
Do not loosen the upper
screws,
plate
B. Do not cut or remove
the ground
strap.
C. Insert the 3 screws
through
each power
cord
Red or
terminal
ring and back
into the terminal
block. Be
Black
certain
the white
wire is in the (:enter. Securely
tighten
each screw
(35 to 50 in-lbs.)
Power Cord
Power cord
\
White
FOR CONDUIT
INSTALLATION
A. Loosen
the 3 lower screws
on the terminal
block. Do not
loosen
the upper
screws.
B. Do not cut or remove
the ground
strap,
Terminal
C. Insert the bare wire tip (insulation
stripped
5/8") into the
bottom
terminal
block openings,
Be certain
the white
wire is in the (:enter,
On certain
models,
the wire must
be inserted
through
an opening
in the ground
strap,
Securely
tighten
each screw
onto each wire (35 to 50
Wire
in-lbs.),
tips
NOTE; Aluminum
building
wire may be used but it must be
rated
for the correct
amperage
and voltage,
Conduit
Black
Red or
Black
PROCEEDTO STEP7.
Conduit
r_
4-WIRE INSTALLATION (SEPARATE GROUND WIRE)
AWARNING:
Shock Hazard
The neutral wire and ground strap must be
connected
as shown
below for the range to
be properly grounded. Do not remove
the
ground
strap.
Failure
follow
this instruction
may result
in potential
shock
hazard.
AWARNING:
Fire hazard
Terminal block screws must be securely
tightened.Failureto do so may resultin
potentialfire hazard.
FOR POWER
CORD
INSTALLATION
A. Remove
the 3 lower screws from the
terminal block. Do not loosen the upper screws.
After-Power
Cord
B. Remove
the ground
screw
and ground
plate
and retain them.
C. Cut the ground
strap below
the terminal
__,_
#___
block and discard
the lower section.
Terminal
D. Insert the ground
screw
through
the ground
block
,._I_I
plate (removed
earlier)
and back
into the
°_X-
range
frame.
Tighten
securely,
but do not
over-tighten
(15 to 20 in-lbs.)
Red or
E. Insert the 3 terminal
screws
through
each
Black
_
\x_
power
cord
terminal
ring and back
into the
terminal
block.
Be certain
the white
wire is
in the (:enter.
Securely
tighten
each screw
(35 to 50 in-lbs.
FOR CONDUIT
INSTALLATION
A. Remove
the 3 lower screws from the
terminal block. Do not loosen the upper screws.
B. Remove
the ground screw and ground plate
and retainthem.
Before-Power
Cord and Conduit
Terminal
//_--_/L_'x_XX_
Ground
strap
block
--
ii-_}l
or
Ground
f
_
_,
strap
Neutral
terminal
White
,_
Ground _
screw
or Bare
After-Conduit
Neutral
Ground
plate
(grounding
to
range)
\
Red or
Black
C. Cut the ground
strap below
the terminal
block
and discard
the lower
section.
D. Insert the bare ground
bare wire tip (insulation),e![_l,
inal --'-'_
stripped
5/8") between
the range
frame
UIUt_R
and the ground
plate (removed
earlier)
and secure it in place
with the ground
Wire
screw.
Tighten
securely,
but do not over-
tips
tighten
(15 to 20 in-lbs).
E. Insert the wire tips (insulation
stripped
5/8")
Black
into the bottom
terminal
block openings.
Be
certain
the white wire is in the center.
On
certain
models,
the wire must be inserted
Ground
through
an opening
in the ground
strap,
screw
Securely
tighten
each screw
onto
each wire
(35 to 50 in-lbs.)
Ground
plate
(grounding
to
_ange)
Red or_
Green
or Bare
NOTE: Aluminum
building
wire may be used but it must be rated
for the correct
amperage
and voltage.
31-10980
08-14
GE

Publicidad

loading

Este manual también es adecuado para:

24" wide