any reading given at a position differing +/- 15° from the upright position is not to be
considered realistic. The indicator is supplied to check the airflow; it is not suitable to
check the capacity or the running time of the battery.
7.9
Replace the hood if damaged (cracks, bumps etc.) as this could cause inward
leakage.
7.10 This equipment is to be used only by qualified personnel who has been trained on
The use and maintenance of Respiratory Protective Devices and who is aware of
their technical and legal limits.
7.11 Do not use the respirator if your sense of smell is in any way impaired.
7.12 Do not use the respirator if it has not been serviced annually by a Kasco authorized
service centre.
8.
REPAIRS
8.1. Use only genuine KASCO spares.
8.2.
Should you require technical assistance please fill out the form on our website and
possibly include the following information : Respirator type – Serial number – Retailer name
– Problem experienced – Voltage type – Hazard type and concentration – Type of filter
used – Frequency of usage– A job description if useful to identifying the problem.
9.
MARKINGS
The CE mark certifies compliance with the essential health and safety
requirements in Annex II of Regulation (EU) 2016/425. The number 0426
after EC identifies the Notified Body ITALCERT control institute of the
finished product in accordance with Regulation (EU) 2016/425.
EXPIRY –year – month
HUMIDITY – maximum
admissible in storage area.
INSTRUCTIONS to be
read before use
a)
Example of Air System label:
The label is affixed on the carton containing the Air System.
Company logo
Product name and code
Reference standard
Serial number
The PPE for respiratory protection obtained by combining AIRSYSTEM with a hood have been CE certified in accordance with regulation 2016/425/EU and subsequent amendments
as category 3 PPE, by ITALCERT, V.le Sarca, 336 - I 20126 MILAN; Notified Body no. 0426. The CE marking means compliance with the essential health and safety requirements
set out in Annex II of Regulation 2016/425/EU. The number 0426 next to the CE identifies the ITALCERT Notified Body responsible for checking the finished product pursuant to
regulation 2016/425/EU. The EU Declaration of Conformity can be downloaded from our website
NOTES:
Operating temperature range
Operating humidity range
Charging temperature range
Equipment run time
LI-02 BATTERY CHARGER INSTRUCTIONS USE
TECHNICAL CHARACTERISTICS :
Type of battery
Battery
model
Rechargeable
LI-870
LITHIUM
8700 mAh
Short circuit cut off device.
Automatic switch over for charge maintenance when battery reaches 90% of its charge(GREEN
LED)
Environment temperature compensation device.
ISTRUZIONI D'USO – USE INSTRUCTIONS – GEBRAUCHSANLEITUNG
– MODE D'EMPLOI - INSTRUCCIONES PARA EL USO - INSTRUÇÕES
DE USO - KÄYTTÖOHJEET - BRUKSANVISNING - INSTRUKSJONER
FOR BRUK - GEBRUIKSAANWIJZING - Οδηγίες
STORAGE
TEMPERATURE -
minimum/maximum
Year of PRODUCTION
DISPOSAL - diversified
From 0°C to 40°C
From 0°C to 80%
From 0°C to 40°C
Below 0°C and above 40°C the battery may not accept charge
See table at point 2.2
time specified in the table at point 2.2 assumes operation with clean filters and fully charged batteries. Different conditi ons will
produce varying run times.
Battery
Inlet
charger model
voltage
[V]
LI-02
110-220V
cod. 0105079
50-60Hz
b)
Hood label. Contains the following info:
Product name and code
c)
Example of the label affixed to blower units:
d)
Example of label affixed to batteries:
e)
Example of label affixed to filters:
10 TRANSPORT
The powered respirator is to be kept in its original packaging during transport.
11. STORAGE
Store powered respirators and filters in their original packaging at a temperature
between 0°C and +40°C and a humidity lower than 80%.
12. WARNING
12.1 BEFORE USE CHECK THAT PRODUCT CODE NUMBERS, TYPE AND
QUANTITY OF SUB ASSEMBLIES CORRESPOND TO THOSE LISTED ON THE
RESPIRATOR COMPOSITION CHART.
12.2
Kasco retains any type of warranty forfeited on the instant and declines any liability
either direct or indirect should our Use and Maintenance instructions not be adhered
to and should filters and spares other than genuine Kasco filters and spare be used.
12.3 The liability for the proper operation of the respirator is irrevocably transferred to the
respirator purchaser or operator if:
a)
the prescribed maintenance is not carried out and/or repairs and maintenance
are carried out on the respirator Sby personnel not employed by or service
centres not authorized by KASCO.
b)
the respirator is used in a manner not conforming to its intended use as specified
in the relative product certification/approval.
12.4 IMPORTANT:
Adhere strictly to all instructions, labels and limitations pertaining to this equipment. If
instructions and warning are not adhered to at all times, respirator effectiveness will
diminish and wearer protection will be reduced.
at:
https://kasco.eu/en/download-area/
The equipment run time is strongly influenced by the conditions of the filter and other factors. The run
USE INSTRUCTIONS
Charging
Charging
current
time
[A]
[h]
3
< 3
CAUTION
Rev. N. 1 del 11/05/2020
Company logo
Serial number
Plug the battery charger into mains.
Connect battery charger outlet plug to the discharged battery.
Battery recharging is automatic. ( RED LED) Keep LI-870 battery
under charge at least and 2,5 hours.
The battery charger may remain plugged into the fully charged
battery with no overcharge risk provided it be under tension.
Store in a dry place.
Use only genuine Kasco spare parts.
IST-USO-0906018