Operating Instructions
Each appliance burner is tested and calibrated at the factory prior to shipment; however, variations in the local gas
supply may make it necessary to adjust the burner. Please visually check the flames of the burner. Always visually
inspect your appliance before lighting. Replace any hose that is frayed or cracked. Look for anything that could
block ventilation and remove such a blockage or move the appliance. After lighting, check the flame pattern to
ensure you have even heat distribution for the burner. If burner don't light up, or if the flame pattern is uneven, see
the Troubleshooting section.
1. Read the instructions before lighting.
2. If the burner does not ignite in 5 seconds, turn the regulator valve off, wait 5 minutes and repeat the lighting
procedure.
3. Inspect the gas supply hose prior to turning the gas "ON". If there is evidence of cuts, wear, or abrasion,
it must be replaced prior to use. Do not use the appliance if the odor of gas is present. Only use the pressure
regulator and hose assembly supplied with the unit.
4. Never use regulators and hose assemblies other than those supplied with the appliance. If a replacement is
necessary, contact the manufacturer to get the proper replacement. The replacement must be as per the
specifications in the Owner's Manual. DO NOT LEAVE THE APPLIANCE UNATTENDED WHILE COOKING.
LIGHTING THE BURNERS USING ELECTRONIC IGNITION
1. Ensure the regulator valve is completely closed.
2. Open gas cylinder valve by turning counterclockwise.
3. Open the regulator valve by turning clockwise.
4. Push and hold ignitor button to light the burner.
5. If the burner does not ignite, turn off the regulator and cylinder valve, wait for 5 minutes before attempting to
relight the burner.
6. If the burner ignites, turn the regulator valve to the desired heat setting.
* Should the burners still fail to ignite, check the gas supply.
MANUALLY LIGHTING THE BURNERS WITH MATCH STICK
1. Ensure the regulator valve is completely closed.
2. Open gas cylinder valve by turning counterclockwise.
3. Open the regulator valve by turning clockwise.
4. Place a match in the match holder. Match holder is attached to cart.
5. Use the holder to slide the lit match close to the burner. The burner should light immediately. DO NOT stand with
your head or arms over the burner.
6. If the burner does not ignite, turn off the regulator and cylinder valve, wait for 5 minutes before attempting to
relight the burner.
7. If the burner ignites, turn the regulator valve to the desired heat setting.
* Should the burners still fail to ignite, check the gas supply.
TURNING OFF YOUR APPLIANCE
1. Turn off the gas supply at the LP cylinder by turning the valve clockwise to a full stop.
2. Turn off the regulator by turning the valve counterclockwise to a full stop.
!
WARNING:
BEFORE LIGHTING
7
!