Descargar Imprimir esta página

Mitsubishi Electric MXZ-2F33VF3 Manual De Instalación página 8

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
1-5. INSTALLATION DIAGRAM
Open as a rule
More than 500 mm
if the front and both
sides are open
en
More than
100 mm
Open as a rule
More than 500 mm if the back,
both sides and top are open
*1 The manufacturing year and month is indicated on the spec name plate.
ACCESSORIES
Check the following parts before installation.
(1) Drain socket*2
PARTS TO BE PROVIDED AT YOUR SITE
(A) Power supply cord*3
(B) Indoor/outdoor unit connecting wire*3
(C) Extension pipe
(D) Wall hole cover
(E) Piping tape
Extension drain hose
(F)
(or soft PVC hose, 15 mm inner diameter or
hard PVC pipe VP16)
(G) Refrigeration oil
(H) Putty
(I) Pipe fixing band
(J) Fixing screw for (I)
(K) Wall hole sleeve
Soft PVC hose, 15 mm inner diameter or hard
(L)
PVC pipe VP16 for drain socket (1)
Note:
*2 2F53VFH3 is not provided with the drain socket.
*3 Place indoor/outdoor unit connecting wire (B) and power supply cord (A)
at least 1 m away from the TV antenna wire.
The "Q'ty" for (B) to (K) in the above table is quantity to be used per indoor unit.
1-6. DRAIN PIPING FOR OUTDOOR UNIT
Please perform the drain piping work only when draining from one place.
1) Provide drain piping before indoor and outdoor piping connection.
2) Connect the soft PVC hose (L) I.D.15 mm as shown in the illustration.
3) Make sure to provide drain piping with a downhill grade for easy drain flow.
Note:
Install the unit horizontally.
Do not use the drain socket (1) in the cold regions. Drain may freeze and it
makes the fan stop.
The outdoor unit produces condensate during the heating operation. Select
the installation place to ensure to prevent the outdoor unit and/or the grounds
from being wet by drain water or damaged by frozen drain water.
6
After the leak test, apply insulating material tightly so
that there is no gap.
When the piping is to be attached to a wall containing
metals (tin plated) or metal netting, use a chemically
treated wooden piece 20 mm or thicker between the wall
and the piping or wrap 7 to 8 turns of insulation vinyl tape
around the piping.
To use existing piping, perform COOL operation for 30
minutes and pump down before removing the old air
conditioner. Remake flare according to the dimension for
new refrigerant.
*1
More than 100 mm
More than 200 mm if there are
obstacles to both sides
More than 350 mm
1
1
1
1
1
1
1
Little
amount
1
Units should be installed by licensed contractor according to local code
2 to 7
requirements.
2 to 7
1
1
WARNING
To avoid risk of fire, embed or protect the refrigerant
piping.
External damage on the refrigerant piping can be
cause of fire.
Outdoor unit installation
800
150
500
Air inlet
Air inlet
Air outlet
2-10 × 21 Oval holes
(L) Soft PVC hose
(1) Drain socket
(Unit: mm)

Publicidad

loading

Este manual también es adecuado para:

Mxz-2f42vf3Mxz-2f53vf3Mxz-2f53vfh3