Flexmount 3" Blower Model 35515-Series
FEATURES
• Tough Reinforced Plastic Housing
• Universal Flexmount Bracket Permits Outlet to Face Any
Direction
• Slip-On Inlet and Outlet Ducting Connection
• Efficient High Volume Air Flow
• Low Current Draw
• Corrosion-Resistant Materials Throughout
• N.M.M.A. Type Accepted
• Meets USCG Regulation 183.410 and ISO 8846 MARINE for
Ignition Protection
• Complies with ISO 9097 MARINE
INSTALLATION
INSTALLATIONS MUST MEET APPLICABLE SECTIONS OF TITLE
33, PART 183; SUBPART K, USCG VENTILATION REGULATIONS.
MOUNTING: Mount blower on flat bulkhead surface in
highest part of compartment free from spray or deck wash. Blower
may be rotated in mounting bracket to facilitate the shortest route
of ducting. Use a suitable discharge fitting so that static pressure
of blower will not be affected by change in wind direction. Route
inlet ducting with as few bends as possible to lower 1/3 of the
bilge compartment where vapors are likely to accumulate. Be
sure ducting is positioned below top of engine stringers but not
so low as to become submerged in bilge water. Locate pickup to
take advantage of natural air flow direction. Flexible ducting No.
34959-0100 is easy to cut and install. If installed as galley ven-
tilator, blower should be mounted away from extreme heat. For
exposed blower install, ventilator intake screen No. 34764-0000
provides a safe and attractive protected inlet.
Jabsco blowers are primarily intended for intermittent duty cycles
such as evacuating fuel vapors from bilge areas. If desired, they
also may be used for other general air circulation applications
with longer duty cycles. However. when doing so, it should be
noted that the maximum motor life is approximately 1000 hours.
Therefore, the blower should only be used for applications if this
length of service is acceptable. For continuous duty applications,
ask your dealer about Jabsco Heavy Duty Long Life Blowers.
NOTICE: Blower should be mounted away from extreme heat
(more than 130°F (54ºC)) to prevent distortion of blower wheel
or housing.
OPERATION: See following warning placard statement.
WARNING: Explosion hazard.
Gasoline vapors can explode. Before
starting engine, operate blower for 4
minutes and check engine compartment bilge for gasoline
vapors. Run blower below cruising speed. Failure to do so can
result in injury or death.
SPECIFICATIONS
OPEN AIRFLOW:
VOLTS:
AMPS:
FUSE SIZE:
WEIGHT:
WIRING: Use marine grade stranded copper wire. For lengths
up to 25 feet (7.6 m) from power source: Use 16 gauge wire for
12 Volt. Use larger wire for longer lengths. Use a 10 amp rated
on-off switch in positive side of circuit. Circuit must be protected
with a fuse.
INSTALLATION DRAWING
To Discharge
Vent
3" Ducting
No. 34959-0100
Inlet Ducting
The "WARNING" placard supplied with blower must be
mounted adjacent to engine ignition switches (all locations)
to comply with Title 33, Part 183; Subpart K, USCG Ventilation
Regulations.
3
105 CFM (2,9 m³/min)
12 Vdc
4.3 Amps
6 Amps
3.5 lb (1,6 kg)
Bulkhead