On / Off and light
·
Press and hold button (1) briefly to switch the device on.
·
Pressing button (1) several times switches the flashlight on/off.
·
Press and hold button (1) for at least 5 seconds to switch the device off.
1.6.2
Wiring test
Test setup:
The wiring test can be used in the following variants:
1. With built-in remote or additionally available remotes:
Connect the main unit to one end of the wiring and the remote to the other end of the wiring.
In this mode, a full wiring test with length measurement is performed.
2. Identify with port.
Connect the main device to one end of the cabling and a port identifier to the other end of the cabling.
In this mode, only the ID of the connected port is recognized.
3. Open end.
Connect the main device to one end of the cabling and leave the other end open.
Attention: A wiring test is carried out, but certain error states such as twisted pairs cannot be detected in this
mode.
·
Press button (5) to access the wiring test menu.
·
Press the OK button (7) to start the wiring test.
·
The wiring test is displayed graphically.
·
In modes 1 and 3, the length of each wire pair is displayed to the right of the pair.
·
The set capacitance of the cable is displayed in pf/m below the wiring diagram.
This is required for the length calculation.
If the length of the wire pairs is not correct, the capacitance of the cable in pf/m must be adjusted.
This can be adjusted in the
·
The ID of the respective remote is also recognized under the wiring diagram
1.6.3
PoE
The PoE test checks the PoE class of the connected switch port and briefly queries PoE up to a maximum of 90W.
·
Press the button (4) to access the PoE menu.
·
Press the OK button (7) to start the PoE test.
The PoE test takes a few seconds depending on the switch. The symbol in the top left-hand corner of the screen
shows the test progress.
o Gray circle segments, rotating:
o Red cross:
o Green tick:
A test is considered passed if the desired PoE class is provided by the switch.
·
By default, the CableMaster PoE is tested for the maximum PoE class available.
·
The desired PoE class can be set using buttons (2) and (6).
The following values are displayed:
Mode
Polarity P1
Polarity P2
Type
CableMaster PoE Manual, Multilingual
ElementFunction
1
ON / OFF and light
2
Cursor up
3
Settings
4
PoE test
5
Wiring test
6
Cursor down
7
OK BUTTON
8
Tone generator
9
Length test
Settings
menu.
21
test running
test not passed
Test passed
Mode
Polarity on pair 1
Polarity on pair 2
PoE Type
12