STORING ONE OR MORE ACCESS CODES ONTO THE RELAY OUTPUT A
1) Carry out the electrical connections to the MAIN PCB (Pic.8).
2) Set only one of the switches DIP 1 or DIP 2 or DIP 3 or DIP 4 to ON (It is
through the first four DIp-switches that different ACCESS CODES can be
stored). The red led 1 on the main PCB flashes.
3) Press the ACCESS CODE (from 1 to 6 digits) - press A.
The green led goes on followed by a long confirming beep.
4) Set all DIP-switches to OFF. The red led 1 on the PCB goes off.
NOTE: The relay A can take up to 4 different access codes max. Each code is
to be stored individually by setting any one of the first 4 DIP-switches to ON.
STORING ONE OR MORE ACCESS CODES ONTO THE RELAY OUTPUT B
1) Carry out the electrical connections to the MAIN PCB (Pic.8).
2) Set only one of the switches DIP 1 or DIP 2 or DIP 3 or DIP 4 to ON (It is
through the first four DIp-switches that different ACCESS CODES can be
stored). The red led 1 on the main PCB flashes.
3) Press the ACCESS CODE (from 1 to 6 digits) - press B.
The green led goes on followed by a long confirming beep.
4) Set all DIP-switches to OFF. The red led 1 on the PCB goes off.
NOTE: The relay B can take up to 4 different access codes max. Each code is
to be stored individually by setting any one of the first 4 DIP-switches to ON.
HOW TO OPERATE WITH DGT 61 KEYPAD
Once satisfied that the main PCB is properly connected to the Elpro control
box, and the selected ACCESS CODES stored with the required output, to operate
with the keypad just press the keys corresponding to the ACCESS CODE,
followed by the key corresponding to the required OUTPUT (A or B).
The green led goes on followed a long confirming beeping.
If the access code sequence is
incorrect: the unit gives out 3
beeping souds and the red led
illuminates for 2 seconds. Dial
correctly or reprogram the unit.
ENABLING THE STOP BUTTON KEY
Carry out the electrical connections to the keypad, main PCB and the Elpro
control box (or to a control relay). Pic. 8.
The DGT 61 keypad incorporates also a pure NC contact to get the STOP function.
The contacts of the C - NC terminals on the main PCB are opened on
pulsing the STOP button in the keypad, and no code is required to be entered.
MEMORY CLEARING
PLEASE NOTE: this operation erases completely all the access codes and any additional functions stored with the relay involved in this process.
!
1) Set the Dip-sw. 10 to ON. The red led 1
flashes.
2) Press the key 9 9 9 (three times).
3) Press button A or B to erase the encoding
and the functions from output A or B
4) Set all the DIP-switches to OFF.
5 short beeps confirm the operation
while the green led keeps flashing as
long as beeping can be heard.
DIGITAL KEYPAD
3
Red led
n°3 short beeps
for 2 seconds
Diagram
1)
2)
ON
10
main PCB
keypad
Diagram
1)
2)
ON
1
main PCB
ACCESS
CODE
Diagram
2)
1)
ON
1
main PCB
ACCESS
CODE
Diagram
1)
2)
ACCESS
A or B output
CODE
Diagram
STOP
pure contact
C
NC
S
main PCB
press
3)
or
A or B output
11
3)
4)
main PCB
relay A
3)
4)
main PCB
relay B
or
green led
BEEP
for 1 second
STOP
red led
for 2 seconds
4)
ALL DIP-SW.
TO OFF
5
10
n°5 Beeps
OFF
main PCB
ALL DIP-SW.
TO OFF
1
OFF
ALL DIP-SW.
TO OFF
1
OFF
green led