Technical data
Capacity (pressurisation and air fl ow)
kPa
30
25
20
15
10
5
0
50
100 150 200 300 m
DC 3800 H Turbo EX
Description
Th e DC 3800/5800 H Turbo EX is an electrically operated,
robustly constructed dust extractor for use in conjunction
with dust-generating operations in industry. Dust extractors
of Type 22 are suitable for the collection of fl ammable dust
in Zone 22. Industrial dust extractors are intended to be
used for the suction and removal of dust deposits. Explosion
protection is provided by the insulation of the electrical
parts and the potential equalisation of the components that
come into contact with dust. Th e machine can be used at
temperatures between +10 and +40 °C. Th e DC 3800/5800
H Turbo EX is suitable for general cleaning operations.
Regular cleaning of the workplace is important to prevent
dust explosions.
Th e machine operates with negative pressure. Separation of
the coarse particles takes place in a cyclone, and separation
of the fi ne dust takes place in the fi lter unit.
Th e material is separated into a container that is attached
directly to the cyclone. Th e fi lter is cleaned using reverse
pulse.
Th e material that has been vacuumed up and fi ltered is
collected in a container with a capacity of 40 litres with a
plastic sack insert (part no. 42384H). Th e container can
be removed with a simple movement of the hand, and the
material is thus easily disposed of. Carefully remove the
full sack from
the edge of the bin and immediately seal it tight. Th en place
2014-04-10
kPa
30
25
20
15
10
5
3
/h
0
a new plastic sack in the bin, and carefully pass the opening
back over the edge of the bin, ensuring that no damage is
caused, and such that no folds are visible.
ATEX
Th e machine and accessories are suitable for use in Zone 22
(1999/92/EC) for the suction and removal of:
II 3D
Ex tc IIIC T1250 C Dc IP65 X, 10<= t
with and without accessories, in order to collect com-
bustible dust in an atmosphere (Zone 22) designated
as explosive.
CAUTION! This machine contains hazardous dust.
Emptying and any maintenance operations, includ-
ing the removal of dust collection containers, must
only be carried out by specialist personnel, who
must wear the appropriate protective equipment. Do
not operate without the complete fi ltration system.
DC 3800/5800 H Turbo EX - 14
200 400 600 800 1000 m
DC 5800 H Turbo EX
This Standard covers the safety of dust extractors
with electric motors, including dust separators and
back-pack vacuums, used for wet extraction, dry
extraction, or wet-and-dry extraction, supplied
for commercial use indoors and for outdoor use
Part No 94125-G
3
/h
<=40
o
C
a

Publicidad

loading

Este manual también es adecuado para:

Dc 5800 h turbo ex