This icon appears in the display.
Use these buttons to set temperature measurement to ºC or ºF.
Temperature option (setting the range)
You can adjust the upper and lower limit for the temperature monitor. An alert will occur if the
temperature becomes outside the preset temperature range.
Press the button three times (lower limit) or four times (upper limit).
This icon appears with the current setting in the display (Lo = lower limit / Hi =
upper limit).
Use these buttons to adjust the limits (lower limit Off, 12, 15, 18 / upper limit: 20, 23, 26,
Off). When set to "Off" the temperature monitoring is deactivated.
Switching the night light on/off
Press the button five times.
This icon appears in the display.
Use these buttons to switch the night light on the transmitter on or off.
Switching the vibration alarm on/off
Press the button six times.
This icon appears in the display.
Use these buttons to switch the vibration alarm on or off.
When the vibration alarm is activated, the receiver vibrates when sounds in the room being
monitored are so loud that the red Sound Level LEDs are activated.
Adjusting the VOX sensitivity
(VOX: Voice Operated Transmission = Sound detection)
The VOX function (sound detection) causes the system to start transmitting automatically from
the transmitter to the receiver immediately a voice or
sound is detected.
Press the button seven times.
This icon appears in the display.
Use these buttons to set VOX to OFF or adjust the sensitivity to one of 5 levels (5 =
highest sensitivity). When one of the five levels has been set, the VOX icon lights up in
P-7