Section 4: Operation
the
Engine
I.
Turn OFF and unplug all electrical loads from generator
pane[ receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
2.
Let engine run at no°load for several minutes to
stabilize internal temperatures
of engine and generator.
3.
Turn engine off according to instructions
given in the
engine operator's
manual
4.
Hove fuel valve to "Off"
position.
[ 20 Volt AC, 20 Amp,
Duplex
Both duplex receptacles (Figure 6) are protected
against
overload by a double pole rocker switch circuit breaker.
1
, NEVER attempt to power a device requiring more amperage
than generator
or receptacJe can supply.
, DO NOT overload the generator_ See "Don't Overload
Generator".
[ 201240 Volt AC, 30 Amp,
Locking
Use a NEHA
LI 4-30
plug with this receptacle.
Connect
a
4-wire
cord set rated for 250VoltAC
loads at 30 Amps (or
greater)
(Figure 5).You can use the same 4-wire
cord if you
_lan to run a 120Volt
load.
4-Wire
Cord Set
/
/
\
(Neutral)
NEMA
LI4-30
/--717
Ground
(Green)
This receptacle
powers
120/240VokAC,
60 Hz, single
phase loads requiring
up to 5,550 watts of power
(5.55 kW) at 23. I Amps for 240Volts
or two independent
120Volt loads at 23. I Amps each.The
outlet
is protected
by a double pole rocker
switch circuit breaker.
Use each receptacle
to operate
120VokAC,
single-phase,
60 Hz electrical
loads requiring
up to 2,400 watts
(2.4 kW)
at 20 Amps of current.
Use cord sets that are rated
for
125 Volt AC loads at 20 Amps (or greater).
G E N E RATO R ADAPTE
R
CORD
SET
The generator
comes with a 25' generator
adapter
cord set
designed to provide two sets of 120Volt_ 20 Amp outlets from
one
120Volt, 20Amp
duplex receptacle
(Figure 7).The
generator
adapter
cord set provides a convenient
supply of
emergency
power so that your generator
can be operated
safely outside.
The maximum
load on each outlet
is 20 Amps.The
maximum
total load on both black wire outlets
or white
stripe wire outlets
is 20 Amps.
NOTE:
Follow all safety precautions
when
connecting
any
extension
cord or device to the generator.