Error messages
Faults caused by the electronic control system will be shown in the LCD
display, alternating with the standard display (fig.13). In addition, the back-
lighting facility will be activated to alert the operator to the error.
The following error messages may be displayed:
Display
Error when measuring the room temperature,
Error 1
room temperature sensor or its cable defective
Error when measuring the core temperature,
Error 2
core sensor or its cable defective
Defective charging process, core temperature after
Error 3
charging too low or fell too steeply during charging
Temperature too high on the control module or
Error 5
Clock faulty. Causes:
1. "Loss of voltage" message when starting the
Error 7
appliance.
2. Scanning of an implausible time.
3. Error when verifying a newly-programmed time.
Error 8
Error 9
Internal error in the operating element
Table 2
1)
If the fault persists despite attempting to shut the appliance down several times, one must assume that there is
an internal defect in the module.
Before making a customer service call, you should obtain the error message so that you can set aside the requisite
spare parts ahead of time
Description
operating element
Internal error in the control
Fig.13
Effect
Discharge control is
switched off
Charge control is
switched off
Charge control is
switched off
Entire appliance is
switched off
1. Display only
2. and 3. Entire
appliance is
switched off
Display only,
additional information
available in the
Technicians menu
Display only,
additional information
available in the
Technicians' menu
Deletion through
Automatically, once the
fault has been rectified
Automatically, once the
fault has been rectified
Via the 'Error deletion'
menu
Switch off appliance
1)
Re-input the time
Depending on the fault,
via the 'Error deletion'
menu or by switching
1)
off the appliance
Depending on the fault,
via the 'Error deletion'
menu or by switching
1)
off the appliance
39