Indicator lights:
HEATING - The device heats the water.
KEEP WARM - The water has reached the set temperature; temperature maintenance mode.
WATER LOW - No water in the unit - the water supply may be cut off or the water has not reached the
required level (display code: ELL).
WATER FILLING - The device refills the water.
RESERVATION - The unit is operating in the set time mode.
MALFUNCTION - The unit is malfunctioning. Solve the problem according to the error code
Buttons:
RESERVATION - button for setting the device operation time.
SET - Settings button.
UP/DOWN - Buttons for increasing/decreasing the set temperature and time values.
ON/OFF - the main switch of the device
3.2.
Preparation for operation
POSITIONING OF THE UNIT
The ambient temperature must not exceed 40°C and ambient humidity should not exceed 85%. Place the unit
in a way that ensures good air circulation. Maintain a minimum clearance of 10 cm from any wall of the unit.
Keep the unit away from any hot surfaces. Always operate the unit on a level, stable, clean, fireproof, and dry
surface and out of the reach of children and persons with impaired mental, sensory, and intellectual
functions. Place the unit in such a way that the main plug can be reached at any time. Ensure that the power
supply to the unit corresponds to that specified on the identification plate!
Before using the unit for the first time, disassemble all parts and wash them as well as the entire unit.
1. Place the unit as described above. Place the water tray on the bottom.
2. Screw one end of the inlet tube into the water inlet on the back of the unit.
3. Screw the other end of the inlet tube to a water source or threaded tap.
4. Open the water supply.
5. Connect the device to the power supply.
3.3.
Working with the device
To turn on the device, press the "ON/OFF" button. To turn off the device, press and hold the "ON/OFF" button
for 3 seconds.
When the bolier is turned on for the first time, the appliance will automatically heat up and boil the water
until the keep warm indicator turns on, indicating that the water temperature has reached the set value.
Press and hold the "RESERVATION" button to activate or deactivate the timer operation mode.
To check the set temperature, press and hold the "DOWN" button for 3 seconds.
3.3.1.
Setting the filling time
The machine has a default setting of water refilling for 1 second, while the pause time cannot be changed. If
you want to change the filling time, please follow the instructions below.
For example: set the filling time to 2 seconds and stop for 17 seconds.
Filling the tank with high-temperature water takes 1 second, then it stops for 17 seconds (1 second = code
"20").
If you need to set 2 seconds to fill the water tank (2 seconds = code "40") at high temperature, press SET for
3 seconds in standby mode, select code "
wait 20 seconds to automatically return to OFF, then press ON/OFF lightly to complete the setting.