Ql100 series range hood
!
intended For doMestic cooKinG onlY
iMPortant saFetY instructions
WarninG – to reduce the risK oF Fire, electric shocK,
or inJurY to Persons, oBserve the FolloWinG:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service panel to prevent power from being
switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer's guideline and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Use with approved cord-connection kit only.
8. To reduce the risk of fire, use only metal ductwork.
to reduce the risK oF a ranGe toP Grease Fire:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cook-
ing flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
to reduce the risK oF inJurY to Persons in the event
oF a ranGe toP Grease Fire, oBserve the FolloW-
inG*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it start-
ed.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Firesafety Tips" published by NFPA.
Get user manuals:
See SafeManuals.com
installation instructions
read & save these instructions!
iMPortant saFetY instructions
1. For general ventilating use only. do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To reduce the risk of fire or electrical shock, this range hood
should not be used with an additional speed control device.
3. To reduce the risk of shock, disconnect power before servic-
ing.
4. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside.
Plan the installation
Recommended mounting height is 18" to 24" from the bottom of the
range hood to the top of the cooking surface.
The hood should be mounted to the bottom of a standard wall
cabinet. If the hood must be mounted directly to a wall, secure the
hood to wall studs.
All wiring must comply with local codes and the unit must be properly
grounded. The hood is connected to a 110-120vAC lighting circuit
(15 amp) in the circuit breaker or fuse box.
This range hood is "Convertible" – it may be installed as a ducted
or as a non-ducted unit.
iF the ranGe hood is to Be non-ducted:
Purchase non-ducted (duct-free) charcoal filter Model
BPQTF.
iF the ranGe hood is to Be ducted:
Ductwork can be installed vertically or horizontally.
Duct runs should be as short as possible.
Avoid the use of elbows.
Use duct tape at all joints.
Do not use duct smaller than the discharge on the hood.
For 7" round ductwork installation, use 7" round damper, Model
BP87 (97010792) Purchased damper separately.