Verify the minimum measurements required for correct
installation of the appliance. The coffee machine must be
installed in a column and the column must be firmly fixed to
the wall with commercially available brackets.
IMPORTANT!
• Important: all installation or maintenance operations
must be performed with the appliance disconnected
from the mains electricity supply.
• Kitchen furniture in direct contact with the appliance
must be heat resistant (65°C min).
• To guarantee correct ventilation, leave a gap at the
bottom of the cabinet (see measurements in figure 1).
• Position the rails on the sides of the cabinet as shown in
the figure 2. Fix with the screws provided, then extract
them completely. If the coffee machine is installed over
a warmer drawer, use the top surface of this as a
reference to position the rails. In this case, there will be
no surface to rest the rails on.
3 - Built-in installation
IMPORTANT!
• Fix the power cable with the clip (fig. 3). The power
cable must be long enough to allow the appliance
to be extracted from the cabinet to fill the coffee
bean container. The appliance must be earthed in
compliance with legislation. Electrical connections must
be performed by a qualified electrician following the
instructions.
• Position the appliance on the rails, making sure the pins
are correctly inserted in the housings, then fix it with the
screws supplied (fig. 4). If the height of the appliance
requires adjusting, use the spacer disks provided.
• If necessary, correct alignment of the appliance by
positioning the spacers supplied under or at the sides of
the support (fig. 5).
• The rail fixing panel must have a thickness suited to the
fixing screws provided.
• The panel material must be suited to the machine weight
of approximately 25kg.