Problem
Failure to start or no air
delivery
Inadequate air delivery
with cooler running
Inadequate cooling
Motor cycles on and off
Noisy
Excessive humidity in
house
Musty or unpleasant
odor
Water draining from
cooler
Weight (lbs.)
Peso (libras)
Model No.
Modelo
Dry
Seco
WC35, RWC35
125
WC44
137
WC46, RWC46
152
WC50, RWC50
155
110496-1
Troubleshooting
Possible Cause
1. No electrical power to unit
• Fuse blown
• Circuit breaker tripped
• Electric cord unplugged or damaged
2. Belt too loose or tight
3. Motor overheated
• Belt too tight
• Blower bearings dry
4. Motor locked
1. Insufficient air exhaust
2. Belt too loose
3. Pads plugged
1. Inadequate exhaust in house
2. Pads not wet
• Pads plugged
• Open spots in pads
• Trough holes clogged
• Pump not working properly
1. Low voltage
2. Excessive belt tension
3. Blower shaft tight or locked
4. Bearings dry
1. Bearings dry
2. Wheel rubbing blower housing
3. Loose parts
1. Inadequate exhaust
1. Stale or stagnate water in cooler
2. Pads mildewed or clogged
3. Pads not wetting properly
• Trough holes clogged
• Pump not working properly
1. Float arm not adjusted properly
2. Overflow assembly leaking
General Specifications / Especificaciones Generales
Dimensiones De La Caja (pulgadas)
Operating
Height
Lleno
Altura
202
33 7/16
214
34 1/2
246
34 1/2
249
34 1/2
1. Check power
2. Adjust belt tension
3. Determine cause of overheating
4. Replace motor
1. Open windows or doors to increase air flow
2. Adjust belt tension or replace if needed
3. Replace pads
1. Open windows or doors to increase air flow
2. Check water distribution system
1. Check voltage
2. Adjust belt tension
3. Oil or replace bearings (Unplug unit)
4. Oil bearings
1. Oil bearings
2. Inspect and realign (Unplug unit)
3. Tighten loose parts
1. Open doors or windows
1. Drain pan and clean pads
2. Replace pads
3. Check water distribution system
1. Adjust float
2. Tighten nut and overflow pipe.
Cabinet Dimensions (in.)
Width
Anchura
Profundidad
28 1/8
34 1/8
34 1/8
34 1/8
Remedy
• Replace fuse
• Reset breaker
• Plug in cords or replace if damaged
• Adjust belt tension
• Oil blower bearings
• Replace pads
• Repack pads
• Clean trough and unplug holes
• Replace or clean pump (Unplug unit)
• Clean
• Replace or clean pump (Unplug unit)
Window Opening Req'd (in.)
Abertura Requerida (pulgadas)
Depth
Width
Anchura
28 1/8
21 3/4
28 1/2
21 3/4
34 1/8
21 3/4
34 1/8
21 3/4
Height
Altura
14 3/4
14 3/4
14 3/4
14 3/4
5