Attention! The manufacturer will neither be held responsible for, nor will give any compensation during the guarantee
period for any damage caused, and which is due to inadequate installations not compliant with the instructions.
Before using the appliance, it is necessary to clean it carefully, especially the tub (see paragraph "cleaning and care").
Check the connection of the appliance and start it up following the instructions.
Attention! Use the appliance only under surveillance.
- Never start up the appliance without water.
With pasta cookers it is possible to cook pasta, vegetables, rice, eggs, legumes, etc.
The system must be connected to a drinking water supply with the following characteristics. Failure to do so
automatically invalidates the guarantee
Total hardness: 0,5 to 5°F to prevent the build-up of lime-scale
Pressure: 50 to 250 kPa (0,5-2,5 bar).
Chlorine ion concentration (Cl-): not more than 10 ppm (acceptable value) to avoid damaging the internal steel
elements
pH: over 7
Electrical conductivity: 50 to 2000 µS/cm (20°C)
Check that the water drainage tap is turned off.
1) When powering the device, the red light flashes briefly for about ½ second.
2) In the absence of water in the tank the red light keeps flashing.
3a) Turn on the tap to load the tank to the desired level, which must be higher than the minimum level probe and do not
exceed the maximum level, which is marked on the tank by the symbol (--)
3b) In models with automatic load, the water starts loading and you can select the desired level by pressing the button
with symbol (level button)
4) Switch on the main switch installed above the appliance. Turn the control knob corresponding to the hotplate from
position "0" to the degree of coking desired, between 1 and 4.
The white light shows that the heating element is working
(lever in vertical position) which can only be reached through the cabinet door situated below the appliance.
If the probe does not detect the presence of water in the tank for more than 15 sec. the system disables the heating
element: the alarm is indicated by a flashing red light
When the probe returns to detect the presence of water, the heating element is activated and the red light is turned off
NOTE: the filling phase is monitored by the system through the TIME-OUT.
GB
IT
STARTING UP
INSTRUCTIONS FOR USE
WATER SUPPLY CHARACTERISTICS
TURNING ON
To turn off the appliance, turn the knob into position "O".
The user should be equipped with a suitable container for the
drained water. Insert the outlet pipe as shown on the
drawing and place the container in position. Push the safety device
(A) upwards and move lever (B) to the symbol.
Important: pay attention to the clearance between the appliance
and the edges of the stands.
To carry out this operation, it is necessary to open the outlet tap
ANOMALIES
20
IE
CH
EMPTYING THE TUB MOD. CPT...
EMPTYING THE TUB MOD. CP...

Publicidad

loading

Este manual también es adecuado para:

Cpa-74etxCp-78etxCpa-78etx