Before you store the air compressor,
make sure you do the following:
1.
Review the Maintenance section
on the preceding pages and
perform scheduled
maintenance
as necessary.
2.
Set the On/Auto/Off
lever to
"Off" and unplug unit.
3.
Turn the regulator
counterclockwise
and set the
outlet pressure to zero.
4.
Remove the air tool or
accessory.
5.
Pu!I ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
6.
Drain water from air tank by
opening drain valve on bottom of
tank.
Risk of Bursting,
Water will
condense
in the air tank,
If not
drained, water will corrode
and
weaken the air tank causing
a risk
of air tank rupture,
7.
After the water has been
drained, close the drain or drain
valve.
NOTE: If drain valve is plugged,
retease all air pressure.
The valve
can then be removed, cleaned, and
reinstalled.
8.
Protect the electrica! cord and
air hose from damage (such as
being stepped on or run over).
Wind them loosely around
the compressor
handle. (If so
equipped)
9.
Store the air compressor
in a
clean and dry location.
A13640
18-ENG