Descargar Imprimir esta página

camry Premium CR 7926 Manual De Uso página 7

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
- When the room temperature <24 ℃, the unit will automatically select high fan speed mode "M..".
DEHUMIDIFYING "L" mode:
1. The up centrifugal fan will run at low speed, and the speed can't be adjusted.
2. The compressor will stop after running 8 minutes, then run again after 6 minutes.
3. The device adopts constant temperature dehumidifying mode, and the adjustment of temperature is no effective.
COOLING "K" mode:
1. When the room temperature is higher than set temperature on control panel, the compressor starts to run.
2. When the room temperature is lower than set temperature on control panel, the compressor stop and upper fan operates at original set
speed.
Fan "M." mode.
1. The up centrifugal fan runs at set speed, and the compressor does not run. .
2. The adjustment of temperature is no effective.
Timer operation "N":
1. Press "N" button to set Automatic Off time while the unit is running.
2. Press "N" button to set Automatic On time while the unit is ready.
3. The time can be adjusted within a range of 1 hour to 24 hours by pressing the button "D"(+)or "E"(-).
Sleeping mode "I" operation:
1. The sleeping mode operations when the unit is under cooling "K" mode.
2. Press the button "I" in cooling mode "K" , then the unit will work under sleeping mode and the up centrifugal fan will turn to low speed
automatically. The set temperature will increase by 1 ℃ after one hour, and increase 2℃ after two hours. After six hours the unit will stop
running.
Notice:
The main control board has memory function, when the device is ready to run but in stop status, the main control board can memorize the
initialization of working mode. When you turn on the unit, it will work as the same enactment of working-mode as last time, no need to reset
the working mode again. (This condition is not available when the unit is under AUTOMATIC mode "J".)
REMOTE CONTROLLER
1. Slide the back cover to open and take off the isolating film on the batteries.
2. Put the batteries inside the slot, must be corresponding to the signs of "+" and "-" on the remote control.
3. For long time no use, take out the batteries.
4. To prevent environmental pollution, take out the used batteries and dispose safety and appropriately.
To operate the device, aim the remote controller (4) at the signal receptor (3). The remote controller will operate the device at distance 5
meters when pointing at signal receptor of the device.
PROTECTIVE DEVICES
The protective device may trip and stop the appliance in the cases listed below:
1. at cooling mode: indoor air temperature is over 43°C (109°F)
2. at cooling mode: room temperature is below 15°C (59°F)
3. at dehumidifying mode: room temperature is below 15°C (59°F).
If the device runs in cooling "K" or dry "L" mode with door or window opened for a long time when relative humidity is above 80%, dew may
drip down from the outlet.
The protective device will work in the following cases:
1. Restarting the device immediately after stopping work or changing the selected mode while working, you must wait 3 minutes.
2. If the plug has been removed, after restarting the device will return to the original mode, TIMER ON and TIMER OFF - must be set again.
REMARK: there is condensing water recycling hidden within this unit. The condensing water is partly kept recycling between the condenser
and the water plate. When the water level rises to the upper level, the float switch and water full indicator (E4) lights on to remind draining
water. Please cut off the power supply, move the appliance to a suitable place, remove the drain plug, drain water completely. After the
drain, re-install the plug, or the appliance may leak and make your room wet. Drain pipe is added to kit, with inner diameter 9mm, outer
diameter 12mm, material: PVC.
Troubleshooting
1) Trouble: Do not work.
Analysis:
7

Publicidad

loading