1 SAFETY INSTRUCTIONS
❖ INSTRUCTIONS
• This equipment is manufactured in compliance with CE directives. It should be used only by fire-fighting
professionals.
• LEADER, or its subsidiaries, disclaim all liability for any direct, indirect or incidental damages related to the supply,
performance or use of the device.
• Read this manual completely, together with the attached instructions for the use and maintenance of the engine before
starting up or using the equipment.
• Keep fingers and hands away from the turbine.
• This ventilator must be operated or repaired only by qualified, trained staff.
• Do not start up the engine if the blades or the protective shroud show any signs of damage.
• Never move the ventilator when it is running at full speed.
• ESP type blowers must not be used in explosive atmospheres.
• Do not remain in the fan's outlet area (risk of flying debris).
• Keep this equipment out of reach of children.
• Wear safety glasses, gloves and earmuffs when using this ventilator.
• Never allow anyone to use a ventilator without first giving them the necessary instructions.
• Do not wear loose clothing which could get caught in the ventilator.
• Do not use chocks or any other system for increasing the ventilator's tilt angle.
• Use only the accessories provided and validate by LEADER.
❖ MAINTENANCE INSTRUCTIONS
• This equipment should be used or repaired only by fire-fighting professionals.
• Only use genuine spare parts supplied by LEADER. when replacing defective parts.
• During maintenance operations, switch off the power.
2 GENERAL CHARACTERISTICS
•
Chassis in Ø 30 mm/0.10 ft steel tube - epoxy coating.
•
Soft Starter.
•
Electrical system 7.5kW -15.5A (steady-state) and 32A
starting current.
•
Power Supply: 400V - 50Hz three phase 3P+N – IP55.
•
Fan shroud in 3mm/0.01ft sheet aluminium.
•
Turbine made of composite resin – Ø 570 mm/1.87 ft.
•
Noise level around 96.3 dB(A) at 3 m/9.84 ft.
•
Retractable handle, two Ø 230mm/ 0.75 ft wheels.
•
Angle of tilt adjustable (from 10° to 20°).
•
Airflow: 115700 m³/h. /68100 cfm.
L
Pr
10
H
Weight: 75.5 kg/166.45 lbs
+/- 0.5 kg/1.1 lbs
H : 720 mm/2.36 ft
L : 710 mm/2.33 ft
Pr : 678 mm/2.22 ft