CODE
EXPLANATION
5. O0
TIME-OF-DAY
CLOCK, MINUTES
5.00
This is the TIME-OF-DAY CLOCK, minute setting;
select 0-59 minutes by pressing the PERM PRESS
key pad.
-_
Press the WOOLENS key pad once to advance
to next code.
6.00
6.00
TIME-OF-DAY
CLOCK, HOURS
NOTE: Uses the 24 hr. clock
This is the TIME-OF-DAY CLOCK, hour setting;
select 0-23 hours by pressing the PERM PRESS
key pad.
Press the WOOLENS key pad once to advance
to next code.
r. 800
r. 800
TOP SPIN SPEED RPM
This can be selected from the following spin
speeds: 600 rpm, 750 rpm, 800 rpm, 1000
(displays as 999) rpm. Step between speeds by
pressing the PERM PRESS key pad. Factory pre-
set for 800 rpm.
Press the WOOLENS key pad once to advance
to next code.
A1.00
A1.00
PREWASH LENGTH
This is the number of minutes of PREWASH.
Choose 0 to disable the prewash or select between
2 and 7 minutes by pressing the PERM PRESS key
pad.
Press the WOOLENS key pad once to advance
to next code.
A2.03
A2.03
FINAL SPIN LENGTH
This is the number of minutes of final high speed
spin. Choose from 3-8 minutes by pressing the
PERM PRESS key pad.
Press the WOOLENS key pad once to advance
to next code.
If cycle counter (9 0C) is selected, the following is true:
1 00
Number of cycles in
1 02 = 200
HUNDREDS.
2 00
Number of cycles in ONES.
2 2.5 = 25
TOTAL CYCLES = 225 cycles
This is "VIEW ONLY" and cannot be cleared.
-_
Press the WOOLENS button once to advance to
next code.
EXIT FROM SET-UP MODE
Remove power, open console, reinsert plug into AA1, close console,
and apply power.
To enter the "Washer Diagnostic Mode," first enter "Start
Operating Set-up." Then press and hold the DELICATES/KNITS
key pad for 1 second while in set-up code 6, anytime a
diagnostic code is present.
On entry to diagnostic
mode the entire display will flash, a
cycle in process is canceled, money in escrow is cleared, and
diagnostic codes are cleared. If a diagnostic
code persists,
it must be corrected before the following cycle options
are permitted.
There are five possible ways to initiate cycle activity from
diagnostic mode as follows:
1. Washer Cleanout cycle - With the entire display flashing, this
cycle is started by pressing the BRIGHTS key pad.
Use the Washer Cleanout cycle once a month to keep the
inside of your washer fresh and clean. This cycle uses a
higher water level. Use with liquid chlorine bleach to
thoroughly clean the inside of the washer. This cycle should
not be interrupted.
IMPORTANT:
Do not place garments or other items in the
washer during the Washer Cleanout cycle. Use this cycle with
an empty wash drum.
2. Manual Overview Test - With the entire display flashing, this
cycle is started by pressing the WHITES key pad. This cycle
provides more typical full length fills, tumbles, drains, and
actuator dispenser movement, allowing for a more thorough
analysis of the washer operation, including pressure switch
behavior.
3. Quick Spin Cycle - With the entire display flashing, this cycle
is started by pressing the COLORS key pad. This cycle
provides a method to quickly drain and spin (remove water
from the washer) if desired.
4. Quick Overview Test - With the entire display flashing, this
cycle is started by pressing the WOOLENS key pad. This
cycle provides a quick verification that the cold and hot water
valves, dispensers, and pump motor are working, as well as
actuator dispenser movement. It also includes door lock,
drain, and spin operations.
Pressing the DELICATES/KNITS
key pad will exit diagnostic
mode and cancel a diagnostic cycle in process.
DIAGNOSTIC
CODES
If one of the following has occurred, the appropriate diagnostic
code will be in the display.
d9
Low voltage detected for 8 seconds.
F20
Slow Fill. The washer will not detect water input for
4 min. Pressure switch failure or no water inlet. This
code is reported as d8 on d7.
F22
The door is not able to lock. Door lock error or
someone trying to start the washer, by pressing the
door switch with their finger.
(For any other display consult service personnel)
11