Descargar Imprimir esta página

Trumpf TruTool TPC 165 Manual Del Usuario página 15

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
3.3 Overload protection device
If the motor load is too high, the motor limits
the input power. The red message light on
the motor lights up.
Let the machine cool down while idling.
u
1
2
3
1
Overload protection device symbol
2
Motor
3
Message light
5 Troubleshooting
Problem
Oil lubrication does not work. Blade or swivel arm dirty.
The electronic signal indicator
lights up, speed decreases.
The electronic signal indicator
flashes, the machine does not
run.
Cut edge deviates from the
marked position.
Blade does not sit fast on the
swivel arm.
Power tool does not switch
on.
5.1 Replace carbon brushes
If the carbon brushes are worn, the
motor stops.
Have carbon brushes checked by a tech-
u
nician and replaced.
Cause
Winding temperature is too
high.
The restart protection has
been triggered.
Chain tension slackens.
Wear on swivel arm.
Carbon brushes are worn.
Translation of the original operator's manual
4 Consumables and
accessories
4.1 Tool selection
For gentle work and good performance,
make sure that the tools are sharp and that
they are changed promptly.
For notes about accessories, spare parts
lists for wearing parts, and tools, see:
TPC 165
(2A1)
Remedy
Clean the blade
u
Let run in idle.
u
Switch off
u
Switch on
u
Tensioning/loosening saw
u
chain
u
Retightening the swivel arm
clamping
u
Replace carbon
brushes [} 9].
EN
 [} 233].
K
 [} 230].
D
 [} 230].
C
 [} 230].
A
 [} 236].
P
15

Publicidad

loading